50
Manual – MOVI-PLC® advanced DHR41B for EtherNet/IP, Modbus/TCP and PROFINET IO
6
CIP object directory
The Ethernet Industrial Protocol (EtherNet/IP)
Ethernet link
object
• Information on the Ethernet communication interface is stored in the Ethernet link ob-
ject.
• Class code: F6
hex
Class
Instance 1
Ethernet connec-
tion X30:1
Instance 2
Ethernet connec-
tion X30:2
Supported
services
Attri-
bute
Access Name
Data type
Default
value [hex]
Description
1
Get
Revision
UINT
0002
Revision 2
2
Get
Max Instance UINT
0002
Maximum instance
3
Get
Number of
Instances
UINT
0002
DHR41B has two Ethernet interfaces
Attri-
bute
Access Name
Data type Default value
[hex]
Description
1
Get
Interface
Speed
UDINT
00000064
Default value = 100
→
Transmission
speed in Mbit/s
2
Get
Interface
Flags
DWORD
•
Bit 0 displays the active link
•
Bit 1 displays full duplex mode
•
Bit 2 ... bit 4 signal negotiation
status
•
Bit 5 shows whether the manual
setting has to be reset
•
Bit 6 indicates a local hardware
fault
3
Get
Physical
Address
ARRAY of
6 USINTs
00 0F 69 xx xx xx
MAC ID
SEW MAC OUI: 00 0F 69
Attri-
bute
Access Name
Data type
Default value [hex]
Description
1
Get
Interface
Speed
UDINT
00000064
Default value = 100
→
Transmission
speed in Mbit/s
2
Get
Interface
Flags
DWORD
•
Bit 0 displays the active link
•
Bit 1 displays full duplex mode
•
Bit 2 bit 4 indicate the negotia-
tion status
•
Bit 5 shows whether the manual
setting has to be reset
•
Bit 6 indicates a local hardware
fault
3
Get
Physical
Address
ARRAY of
6 USINTs
00 0F 69 xx xx xx xx MAC ID
SEW MAC OUI: 00 0F 69
Service code [hex]
Service Name
Class
Instance
01
Get_Attributes_All
X
_
0E
Get_Attribute_Single
X
X
0
0
I
Summary of Contents for DHR41B