Manual – MOVI-PLC® advanced DHR41B for EtherNet/IP, Modbus/TCP and PROFINET IO
6
CIP object directory
The Ethernet Industrial Protocol (EtherNet/IP)
Vardata object
• This manufacturer-specific object is required to use the engineering option of some
of the software tools provided by SEW-EURODRIVE.
• Class code: 64
hex
Class
None of the class attributes are supported.
Instance 1
Supported
services
The standardized service "Get_Attribute_Single" (Service Code 0x0E) returns a data
stream with the maximum data length (attribute 2) when instance attribute 1 is accessed.
The data content is filled with zeros. If a data stream is added to the request telegram
(Service Type Custom), this data is returned in a mirrored form (Vardata test mode).
The Vardata service (service code 0x32) is a manufacturer-specific service. In this ser-
vice, the telegram structure for the request and response are the same. The telegram
contains routing information, the data length of the Vardata user data telegram and the
actual Vardata layer -7 telegram. The data length of the Vardata layer -7 telegram is vari-
able.
The following table shows the complete telegram structure.
Attri-
bute
Access Name
Data type
Default value
[hex]
Description
1
Get
Data
ARRAY OF
SINT
-
-
2
Get
Size
UINT
00F2
Maximum data length in bytes
Service code [hex]
Service Name
Instance attribute 1
Instance attribute 2
0E
Get_Attribute_Single
X
X
32
Vardata (custom)
X
-
Name
Data type
Subaddress 1
BYTE
Subchannel 1
BYTE
Subaddress 2
BYTE
Subchannel 2
BYTE
Data Len Low
BYTE
Data Len High
BYTE
Reserved
BYTE
Reserved
BYTE
FC
BYTE
Vardata
Array of BYTE
0
0
I