5
Configuration examples in RSLogix 5000
Configuration and Startup (EtherNet/IP)
5.4.3
Access to unit parameters of downstream units
Access to the unit parameters of a MOVITRAC
®
B, for example, which is connected to
the CAN 1 system bus of MOVI-PLC
®
advanced
DHR41B is identical with the unit pa-
rameter access to MOVI-PLC
®
advanced
DHR41B itself (see chapter 5.4.2)
The only difference is that
Read/WriteParameterRequest.SubChannel1
, for example,
must be set to
3
and
Read/WriteParameterRequest.SubAddress1
must be set to the
SBus address
of the MOVITRAC
®
B connected to the DHR41B option (see following
figure).
In this example, the value 150 rpm was read from the parameter
P160 Fixed setpoint
n11
(index 8489) of a MOVITRAC
®
B connected to the CAN 1 system bus of DHR41B
with SBus address 7.
For a schematic representation of the parameter access to lower-level units, refer to the
chapter 'Appendix'.