![SEW-Eurodrive CMP40 Operating Instructions Manual Download Page 74](http://html1.mh-extra.com/html/sew-eurodrive/cmp40/cmp40_operating-instructions-manual_1250217074.webp)
74
Operating Instructions – Explosion-Proof CMP Synchronous Servomotors
11
HIPERFACE® resolver signal plug connector assembly
Appendix
8
•
Turn the shield ring until the braided shield
is flush with the shield ring
9
•
Pull the insulator apart evenly by about 1
mm
10
•
Insert the socket contacts into the insula-
tor
11
•
Press the insulator together until you hear
a "click"
12
•
Fold open the insulating sleeve.
•
Position the side of the insulating sleeve
with the recess against the groove in the
insulator so that the opening of the insu-
lating sleeve is pointing in the same direc-
tion as the double-headed arrow on the
insulator
•
Press the insulating sleeve together until it
engages
•
Insert the insulator into the connector
housing in the middle position
13
•
Use a wrench to hold the connector hous-
ing in place and use a second wrench to
tighten the screw fitting
•
[A] = Fix in place
1
"Click"
[A]