Operating Instructions – Explosion-Proof CMP Synchronous Servomotors
71
11
Power connector assembly
Appendix
7
•
Insert a lead with socket contact in the crimping tool and press the tool
fully together. The tool then opens automatically.
•
Repeat this procedure for each lead in accordance with the table in
step 6.
8
•
Open the insulating sleeve.
9
•
Insert the middle socket contact into the insulator according to the wir-
ing diagram.
•
Close the insulating sleeve until it clicks shut.
•
Insert the remaining socket contacts into the insulator according to the
wiring diagram.
10
•
Shorten the braid shield as shown.
•
Insert the shield ring into the seal so that the shield and end of the
cable are flush. Make sure that the braided shield is routed cleanly
between the shield ring and the seal.
11
•
Insert the insulator into the connector housing until the seal rests
against its stop in the connector housing.
12
•
Use a wrench to hold the connector housing in place and use a second
wrench to tighten the screw fitting.
•
[A] = Fix in place
xxx
x
[A]
Summary of Contents for CMP40