Operating Instructions – Explosion-Proof CMP Synchronous Servomotors
17
4
Required tools/resources
Mechanical Installation
4
Mechanical Installation
4.1
Required tools/resources
• Standard tools
• Mounting device
• Operation with conductor end sleeves: Crimping tool and conductor end sleeves
• Crimping tool for plug connectors in case customers want to assemble cables them-
selves
• Removal tool
4.2
Before you start
Do only install the servomotor if the following conditions are met:
• The specifications on the nameplate of the servomotor correspond to the supply sys-
tem (line-powered drive) or the output voltage of the servo inverter (inverter-powered
drive).
• The drive is undamaged (no damage caused by transportation or storage)
• The ambient temperature corresponds to the information on the nameplate and on
the order confirmation.
• The surrounding area is free from oils, acids, gases, vapors, (ionizing) radiation, etc.
• The installation altitude must be no higher than 1000 m above MSL, otherwise the
drive must be designed to meet the special environmental conditions. In case of de-
viations, see nameplate/order confirmation.
4.3
Preliminary
Thoroughly clean the shaft ends and make sure that they are free from anti-corrosion
agent, dirt or the like. Use a commercially available solvent. Make sure that the solvent
does not come into contact with the bearing or sealing rings as it may damage the ma-
terial.
CAUTION!
Observe the safety notes in section 2 during installation.
STOP!
The bearing and the sealing rings can be damaged if exposed to solvents.
Possible material damages!
• Protect the bearing and sealing rings from exposure to solvents.