Operating Instructions – Explosion-Proof CMP Synchronous Servomotors
6
Parameter setting on the servo inverter
Startup
During startup
• The servomotor must run correctly (no overload, no unwanted speed fluctuations, no
loud noises, etc.).
• In case of problems, refer to section 7, "Malfunctions" on page 39.
6.2
Parameter setting on the servo inverter
6.2.1
General information
Observe the relevant operating instructions for servo inverter startup.
6.2.2
Setting the maximum frequency or the maximum speed
The inverter parameters which limit the maximum motor speed must be set according
to the assignment tables for motor/inverter combinations. For gear unit mounting: ob-
serve the maximum speed of the respective gear unit.
NOTE ON EXPLOSION PROTECTION
Install the servo inverter outside the potentially explosive atmosphere.
NOTE ON EXPLOSION PROTECTION
Use the guided startup function of MOVITOOLS
®
MotionStudio or the MOVITOOLS
®
software. It is essential to note that the maximum current limit must be checked/reset
after each guided startup.
Activate the thermal motor protection during startup. Observe the information regarding
the thermal motor protection in section "Thermal motor protection" on page 34.