Operating Instructions – Explosion-Proof CMP Synchronous Servomotors
35
6
Prerequisites for startup
Startup
6
Startup
6.1
Prerequisites for startup
Before startup
• The drive must be undamaged and not blocked.
• The measures stipulated in section "Preliminary work" must be performed after ex-
tended storage page 17
• All connections must be established correctly.
• The direction of rotation of the servomotor/gearmotor must match.
• All protective covers must be fitted correctly.
• All motor protection devices must be active.
• There must not be any other sources of danger.
• No heat-sensitive or insulating materials are allowed to cover the servomotor sur-
face.
HAZARD!
Risk of injury due to electric shock.
Severe or fatal injuries!
•
Observe the safety notes in section 2 during startup.
• Use switch contacts in utilization category AC-3 to EN 60947-4-1 to connect the ser-
vomotor and brake.
• Observe the wiring instructions of the inverter manufacturer.
• Observe the operating instructions for the servo inverter.
NOTE
The rated speed of the servomotor in a gearmotor can be higher than the permitted,
input speed of the gear unit. Set the maximum speed on the servo inverter. For infor-
mation on the procedure, refer to the documentation of the inverter.
NOTE ON EXPLOSION PROTECTION
Before starting up the unit for the first time, make sure that:
• The plug-in connections have been established correctly.
• The plug connectors are protected against inadvertent interruption.