Output ratings
Input
(Vdc)
Function
Short term
rating* (A rms)
Continuous
rating** (A rms)
24
Single traction size 2
300
120
24/36
Single traction size 4
450
180
Single traction size 6
650
260
36/48
Single traction size 2
275
110
Single traction size 4
450
180
Single traction size 6
650
260
72/80
Single traction size 2
180
75
Single traction size 4
350
140
Single traction size 6
550
210
96/110
Single traction size 4
300
120
*2 minute rating (lower ratings are possible for longer periods; see example in Figure 10)
** 1 hour minimum without forced-air cooling
Size 2 long-term rating achievable with finned heatsink approx 250mm x 180mm, 0.5°C/W
Size 4 long-term rating achievable with finned heatsink approx 330mm x 200mm, 0.3°C/W
Size 6 long-term rating achievable with finned heatsink approx 330mm x 280mm, 0.2°C/W
Figure 10 Output current available for various durations of sustained current
demand
Summary of Contents for Gen4
Page 1: ...Gen4 Applications Reference Manual Document no 177 52701 Rev 3 3 ...
Page 9: ...Chapter 1 Introduction ...
Page 13: ...Chapter 2 About the Gen4 ...
Page 25: ...Chapter 3 Installation ...
Page 45: ...Chapter 4 Specification ...
Page 53: ...Specification Doc 177 52701 Rev 3 3 4 9 Dimensions Size 2 models Size 4 models ...
Page 54: ...4 10 Size 6 models ...
Page 55: ...Chapter 5 System design ...
Page 60: ...5 6 Single traction wiring diagram Figure 13 Single traction wiring diagram ...
Page 63: ...System design Doc 177 52701 Rev 3 3 5 9 On board fuse See On board fuse mounting on page 3 11 ...
Page 64: ...5 10 Figure 15 Dual traction wiring diagram ...
Page 70: ......
Page 71: ...Chapter 6 Configuration ...
Page 110: ......
Page 111: ...Chapter 7 Monitoring Gen4 ...
Page 122: ......