On-board fuse mounting
You can mount your main input protection fuse directly onto the controller body as shown below .
Select the appropriate fuse from the table below. Connect the battery positive cable to the
B+ terminal. Connecting to the end
marked ‘+’ (or un-named in the case of size 2) will leave your
installation without a fuse unless located elsewhere in the system. The B+ terminal is a dummy
terminal to allow fuse connection only and has no internal connection.
Figure 5 On-board fuse mounting