Installation
Doc. # 177/52701
Rev. 3.3
3-13
Signal wiring
Assemble your wiring harness using wire of the sizes recommended below and the Sevcon loose
connector kit (P/N 661/27091). The use of twisted pair and in some cases twisted-screened
cables is recommended for the speed sensor and CANbus wiring.
To make a connection, gently push the connector housing onto the appropriate mating half on
the Gen4. Never force a connector. Connectors are keyed to prevent incorrect insertion.
Twisted, shielded wire is recommended. Keep signals away from power cables to avoid
interference. See also ‘EMC guidelines’ on page 3-6.
Signal wire sizes
Use wire between 0.5 mm² (20 AWG) and 1.5 mm² (16 AWG) for all signal wiring. Single twisted
pair cable is readily available in 0.5 mm² (20 AWG).
CANbus termination
See also ‘EMC guidelines’ on page 3-6.
If your system has more than one CAN node, connect the nodes in a ‘daisy chain’ arrangement
(Figure 8) and terminate the connections of the two end nodes with a 120
resistor. If the end
node is a Gen4, link pins 2 and 24 on the customer connector, a 120
resistor is built into the
controller. If you have a single node system the termination resistor should be connected so that
the bus operates correctly when configuration tools are used.
Other CAN node
120
Ω
link
CANbus
P
in
2
4
P
in
2
Gen4
Gen4
Figure 8 CAN node termination
Summary of Contents for Gen4
Page 1: ...Gen4 Applications Reference Manual Document no 177 52701 Rev 3 3 ...
Page 9: ...Chapter 1 Introduction ...
Page 13: ...Chapter 2 About the Gen4 ...
Page 25: ...Chapter 3 Installation ...
Page 45: ...Chapter 4 Specification ...
Page 53: ...Specification Doc 177 52701 Rev 3 3 4 9 Dimensions Size 2 models Size 4 models ...
Page 54: ...4 10 Size 6 models ...
Page 55: ...Chapter 5 System design ...
Page 60: ...5 6 Single traction wiring diagram Figure 13 Single traction wiring diagram ...
Page 63: ...System design Doc 177 52701 Rev 3 3 5 9 On board fuse See On board fuse mounting on page 3 11 ...
Page 64: ...5 10 Figure 15 Dual traction wiring diagram ...
Page 70: ......
Page 71: ...Chapter 6 Configuration ...
Page 110: ......
Page 111: ...Chapter 7 Monitoring Gen4 ...
Page 122: ......