Monitoring
Doc. # 177/52701
Rev. 3.3
7-9
LED
flashe
s
Fault
Leve
l
Set conditions
Operator action
7
Controller high voltage
protection with line
contactor open.
S
Battery voltage or capacitor
voltage is above the maximum
level allowed for the controller
with line contactor open.
Isolate controller and
investigate high
battery voltage
7
Battery voltage below
critical level for
controller.
S
Battery voltage is below the
absolute minimum voltage at
which the controller hardware is
guaranteed to operate.
Increase battery
voltage.
7
Precharge failure
VS
Capacitor voltage is less than
5V after pre-charge operation is
complete.
Check controller
wiring to ensure there
are no short circuits
between B+ and B-.
8
Controller too hot
I
Controller has reduced power to
motor(s) below maximum
specified by user settings due to
controller over temperature.
Remove loading to
allow controller to
cool down.
8
Controller too cold
I
Controller has reduced power to
motor(s) below maximum
specified by user settings due to
controller under temperature.
Allow controller to
warm up to normal
operating
temperature.
8
Motor over
temperature
I
Controller has reduced power to
motor(s) below maximum
specified by user settings due to
motor over temperature.
Reduce load to motor
to allow it to cool
down.
8
Motor too cold
I
Motor thermistor reports less
than
-30ºC.
Allow motor to warm
up. Check motor
thermistor.
8
Heatsink over
temperature
VS
Heatsink temperature
measurement has exceed
absolute maximum for controller
and system has powered down.
Remove loading to
allow controller to
cool down.
10
Pre-Operational
I
Controller is in pre-operational
state.
Use DVT to put
controller into
operational state.
10
I/O initializing
I
Controller has not received all
configured RPDOs within 5s of
power up.
Check CANbus
wiring and PDO
configuration.
10
RPDO Timeout
I / DI
/ S
One or more RPDOs have not
been received within 3s at
power up or within 500ms during
operation.
Check CANbus
wiring and PDO
configuration.
Summary of Contents for Gen4
Page 1: ...Gen4 Applications Reference Manual Document no 177 52701 Rev 3 3 ...
Page 9: ...Chapter 1 Introduction ...
Page 13: ...Chapter 2 About the Gen4 ...
Page 25: ...Chapter 3 Installation ...
Page 45: ...Chapter 4 Specification ...
Page 53: ...Specification Doc 177 52701 Rev 3 3 4 9 Dimensions Size 2 models Size 4 models ...
Page 54: ...4 10 Size 6 models ...
Page 55: ...Chapter 5 System design ...
Page 60: ...5 6 Single traction wiring diagram Figure 13 Single traction wiring diagram ...
Page 63: ...System design Doc 177 52701 Rev 3 3 5 9 On board fuse See On board fuse mounting on page 3 11 ...
Page 64: ...5 10 Figure 15 Dual traction wiring diagram ...
Page 70: ......
Page 71: ...Chapter 6 Configuration ...
Page 110: ......
Page 111: ...Chapter 7 Monitoring Gen4 ...
Page 122: ......