Doc. # 177/52701
Rev3
3-10
Cable sizes
CAUTION: When deciding on power cable diameter, consideration must be given to cable
length, grouping of cables, the maximum allowable temperature rise and the temperature rating
of the chosen cable.
The following table gives guidance on the cable size needed for various currents in welding
cable, not grouped with other cables, in 25°C ambient with 60°C temperature rise on the cable
surface.
Gen4 average (rms)
current
Cable sizes
metric
US
(approx
equivalent)
180 A
25 mm
2
4 AWG
225 A
35 mm
2
2 AWG
280 A
50 mm
2
1 AWG
350 A
70 mm
2
2/0 AWG
Summary of Contents for Gen4
Page 1: ...Gen4 Applications Reference Manual Document no 177 52701 Rev 3 3 ...
Page 9: ...Chapter 1 Introduction ...
Page 13: ...Chapter 2 About the Gen4 ...
Page 25: ...Chapter 3 Installation ...
Page 45: ...Chapter 4 Specification ...
Page 53: ...Specification Doc 177 52701 Rev 3 3 4 9 Dimensions Size 2 models Size 4 models ...
Page 54: ...4 10 Size 6 models ...
Page 55: ...Chapter 5 System design ...
Page 60: ...5 6 Single traction wiring diagram Figure 13 Single traction wiring diagram ...
Page 63: ...System design Doc 177 52701 Rev 3 3 5 9 On board fuse See On board fuse mounting on page 3 11 ...
Page 64: ...5 10 Figure 15 Dual traction wiring diagram ...
Page 70: ......
Page 71: ...Chapter 6 Configuration ...
Page 110: ......
Page 111: ...Chapter 7 Monitoring Gen4 ...
Page 122: ......