IMD Drive installation guide
R1724
- 10 -
SERAD S.A
2-4-
Bottom view
72
233.
5
X12
ANALOG
I/O
X11
RESO
LV
E
R
X13 -
SIN
CO
S
X10 -
BALLAST
/
MOT
O
R
1
2
3
4
5
6
7
8
X10
RB / MOTOR
External braking resistor and motor supply
X11
FEEDBACK
Motor position feedback (resolver / encoder)
X12
ANALOG
Analogues I/O
X 13 SINCOS
Motor position feedbacks (if SINCOS encoder is used)
Care must be taken when making connection to connector X10. An incorrect
connection can seriously damage the drive. Dangerous voltages are present on
X10 (900V).
Wait at least 5 minutes to allow the capacitors to discharge before remove
connector.