IMD Drive installation guide
R1724
- 19 -
SERAD S.A
X10: Motor armature
Connector: Removable 8 ways, 7.62mm pitch
N°
Name
Type
Description
1
RI
Internal braking resistor *
2
RB
Braking resistor *
3
DC Bus +
Out
DC bus +
4
DC Bus -
Out
DC bus -
5
PE
Motor earth
6
W
Out
Motor phase W
7
V
Out
Motor phase V
8
U
Out
Motor phase U
The armoured motor cable must arrive directly on the terminals of the drive.
Connect the shield (on drive side) to the srew provided (see Front view of the drive).
*Selection of the braking resistor:
- Internal resistor:
Fit a link between terminals 1 and 2
- External resistor:
Remove the link between terminals 1 and 2
Connect the external resistor between terminals 2 and 3
Care must be taken when making connection to connector X10. An
incorrect connection can seriously damage the drive. Dangerous voltages are
present on X10.