![Sera PROFIBUS Technical Manual Download Page 9](http://html.mh-extra.com/html/sera/profibus/profibus_technical-manual_1245664009.webp)
www.sera-web.com
9
ELECTRICAL CONNECTIONS
The field bus box modules are connected via the supplied connection cable.
The INTERFACE MODULE has a socket and a plug, whereby no Y-connector is necessary.
The supply voltage (+5 V DC) for the terminating resistor is only applied on the socket.
The terminating resistor is only available as plug connector.
Level connection (1)
Pin
Wire colour
Function (factory setting)
Pin 1
WH
(white)
not assigned
Pin 2
BN
(brown)
not assigned
Pin 3
GN
(green)
not assigned
Pin 4
YE
(yellow)
not assigned
Pin 5
GY
(grey)
not assigned
Pin 6
PK
(pink)
Pre-alarm level
Pin 7
BU
(blue)
Dry run
Pin 8
RD
(red)
GND
The inputs can be switched using a floating contact signal.
Pre-alarm and dry running are set to normally open floating contacts at the factory.
The sockets of the connections are A-coded and the assignations of the functions are symbolically labelled.
PROFIBUS output (2)
Pin No.
Signal
Description
Pin 1
VP
+5 V supply for terminating resistor
Pin 2
A-line
Negative RxD/TxD
Pin 3
GND bus
Data ground
Pin 4
B-line
Positive RXD/TxD
Pin 5
Shield
Not connected internally, connected internally with PROFIBUS cable with shield
Thread
Cable shield
Must be connected externally with PE via cable filter according to PROFIBUS
standard
PROFIBUS input (3)
Pin No.
Signal
Description
Pin 1
NC
NC
Pin 2
A-line
Negative RxD/TxD
Pin 3
GND bus
Data ground.
Pin 4
B-line
Positive RXD/TxD
Pin 5
Shield
Not connected internally, connected internally with PROFIBUS cable with shield
Thread
Cable shield
Must be connected externally with PE via cable filter according to PROFIBUS
standard
ATTENTION
The M12 socket is inversely coded and has 5 pins. Pin 1 is 5 V DC and Pin 3 is GND for the active terminating resistor.
These must never be used for any other functions as this can result in destruction of the device.
Pin 2 and Pin 4 carry the data of the PROFIBUS communication. These must never be reversed otherwise the communicati-
on is disrupted. Pin 5 is the shield that is not internally connected to the module.
RD
BN
GN
YE
GY
PK
BU
WH