25
OPERATION
No. Module Name
Data type Function
Comment
27
ANALOGUE_STATE Byte 1
Bit definition:
0-2
Analogue signal
00
0-20 mA
01
4-20 mA
10
Standardised
Byte 2
Analogue I1
0-200
Byte 3
Analogue Frequency f1
0-100%
Byte 4
Analogue I2
0-200
Byte 5
Analogue Frequency f2
0= 0 mA
150= 15.0 mA
200= 20.0 mA
The current at the active input is displayed.
0-100%
Byte 6
Analogue Current
0-250
28
INPUT1_STATE
Byte 1
Bit definition:
0-3
Input function
0000 OFF
0001 External stop
0010 Venting
0011 Pulse
0100 Analogue changeover
0101 Recipe
0110 Start Batch
4.
NC contact / NO contact
5.
set / not set
29
INPUT2_STATE
Byte 1
Bit definition:
0-3
Input function
0000 OFF
0001 External stop
0010 Venting
0011 Pulse
0100 Analogue 1
0101 Recipe
0110 Start Batch
0111 Batch quantity
1000 Batch output
4.
NC contact / NO contact
5.
set / not set
5. Bit not applicable for analogue function.