![Sera PROFIBUS Technical Manual Download Page 24](http://html.mh-extra.com/html/sera/profibus/profibus_technical-manual_1245664024.webp)
24
www.sera-web.com
OPERATION
No. Module Name
Data type Function
Comment
24
COUNTER_STATE
Float 1
Current delivered quantity
Not calibrated:
Strokes since switching on
or reset
Calibrated
Litres since switching on
or reset
Long 2
(4-byte)
Total delivered quantity
In litres, since delivery of the pump
Long 3
(4-byte)
Total number of strokes
In strokes, since delivery of the
pump
Long 4
(4-byte)
Operating hours
In hours, since delivery of the
pump
Long 5
(4-byte)
Diaphragm hours
In hours, since delivery or last
diaphragm change
25
BATCH_STATE
Byte 1
Bit definition:
0.
Batch is being conveyed
Float 2
Batch volume
Specification according to
BATCH_CONTROL or using analo-
gue input
Float 3
Batch speed
Specification according to
BATCH_CONTROL
Float 4
Remaining batch quantity
0.001 l - max. batch volume
26
PULSE_STATE
Byte 1
Bit definition:
0.
Pulse
1.
Pulse memory
ON/OFF
2-3
Pulse mode
00
Divisor
01
1/1
10
Multiplier
11
Proportional
Word 1
Pulse Memory
Registered pulses
0-999