Advanced Features - Auto-Close Timer
Advanced Features - Auto-Close Timer
Auto-Close Timer Adjustment
When enabled, the auto-close timer can be adjusted for time-out periods between
10 seconds and 250 seconds. Adjustment below or above this range will result in an
error indication. The factory default is 30 seconds.
AUTO-CLOSE TIMER
MENU ITEM
STATUS LED:
2 SHORT FLASH / 2 sec
LRN
E
Press and release
LRN button
e
x1
AUTO-CLOSE TIMER
SUB-MENU
LRN
E
Press and release
LRN button
e
x1
SET
E
Press and release
SET button
e
x1
Increase Time
by 10 seconds
Decrease Time
by 10 seconds
TRIGGER
E
Press and release
TRIGGER button
e
x2
Return to Main Menu
(Advanced Features)
Save Changes and Exit