Limit Programming (cont)
The door will open slowly until the end-stop is encountered. When the endstop is
encountered, the door will stop for a few seconds, then close at full speed, then stop.
It will wait for a few seconds and then open fully at full speed. This is done in order to
measure various parameters needed to set the collision sensitivity automatically,
amongst other parameters.
System Commissioning - Limits
System Commissioning - Limits
L
IS
H
E
N
G
34
1
Door opens slowly in the first stage of limit programming
2
Door homes against metal endstop, this registers the limit.
The motor then stops.
The door will open slowly until the
end-stop is encountered as
shown.
The endstops MUST be
secure or the setup will fail.
The endstops must also be
straight and equally spaced on
both sides to prevent the
formation of gaps when the
door is closed.
Safety inputs (BEAM) and
the trigger input are
unresponsive during this
procedure. Ensure no people,
pets or property can land in the
path of the moving door
curtain.