30
L
IS
H
E
N
G
System Commissioning - Remote LED
System Commissioning - Remote LED
Close up of wall console
Ancillary terminals
GRN
Connection Diagram for installing a remote status LED
A remote STATUS LED allows the user to know the status of the garage door
(open, closed or trouble) from a remote location within his/her residence. A standard
5mm RED LED is required for this feature (not supplied).
No series resistor is required and the line has protection against lightning.
Long Lead (ANODE)
Short Lead (CATHODE)
Flat notch (DENOTES CATHODE)
A
C
RED
RED
BLK
BLK
Take care when mounting the LED on a panel or when bending the
leads apart to solder the wires to them.
The maximum length of cable run is 15 -20 metres. Use thicker cross-
section solid copper wire for longer runs otherwise LED brightness will
be imparied!