No.14S056-01
36
STC-CMC120APCL, STC-CMB120APCL
Specifications and Users guide
5.3.2 Edge Preset Trigger Mode (Exposure timing)
Note.1: The trigger signal is removed by the filter if the pulse width of the input trigger signal is less than 1.5us.
Please input the trigger signal with more than 1.5 us pulse width.
Note.2:
α
1(Exposure time offset) is.
10,8,4,2TAP
41[us] (Edge Preset and Variable at Line unit)
42[us] (Pulse Width and Variable at us unit)
3TAP
42[us] (Edge Preset and Variable at Line unit)
43[us] (Pulse Width and Variable at us unit)
Trigger signal
Exposure time
T1'
Exposure time: T1' = Preset electronic s
α1
Filtering *Note.1
1.5us