No.14S056-01
46
STC-CMC120APCL, STC-CMB120APCL
Specifications and Users guide
Command No.
Command Descriptions
78H:
TESTP[7..0]
[Test Pattern] Initial data: TESTP [7..0] = 00H
This command sets the test pattern video output.
D[7..0]
D7
D6
D5
D4
D3
D2
D1
D0
0: Normal Video Image
1: Gray Scale
2: Ramp
3: 100% White
4: White Clip
6: Color Bar(RGB BAYER)
Others: Black
79H:
EFFCT[7..0]
[Image effect selection] Initial data: EFFCT[7..0] = 00H
This command sets the image effect.
Image data depends on the Tap number of the Camera Link output. If the value is not enough, the value will drop
off.
When the horizontal start pixel position is larger than the actual number, the horizontal start pixel position should
be set to 0.
D[7..0]
D7
D6
D5
D4
D3
D2
D1
D0
D7:
Negative / Positive video selection
0: Positive image
1: Negative image
D6 to D0:
Image effect
00H: No effect (Original)
01H: 9bit gradation
02H: 9bit gradation
03H: 7bit gradation
04H: 6bit gradation
05H: 5bit gradation
06H: 4bit gradation
07H: 3bit gradation
08H: 2bit gradation
09H: 1bit gradation
0A to 7FH: No Function
(Prohibited settings. Do not set these values)
80H:
E2P[7..0]
[EEPROM control] Initial data: E2P[7..0] = 0
D[7..0]
D7
D6
D5
D4
D3
D2
D1
D0
D7 to D1:
No function
Always set as
“0000000”
D6 to D0:
Write control to the EEPROM
0: Prohibited
1: Accept
Note: This bit is cleared to “0” automatically by the internal processes after the command is executed.
81H:
INI[7..0]
[Reload camera default setting] Initial data: INI [7..0] = 00H
This command sets the factory setting.
D[7..0]
D7
D6
D5
D4
D3
D2
D1
D0
Note: Once the camera setting is reloaded, the register may set
“0” automatically. This setting data does not save
on the EEPROM through this register.
D[7..0]:
Factory Setting
0: No Function
170: Reload factory setting
Summary of Contents for CL Series