No.14S056-01
63
STC-CMC120APCL, STC-CMB120APCL
Specifications and Users guide
9 Actual Camera Setting & Technical Notes
9.1 Using the Trigger Signal through 6pin
1. Select
“[0] Trigger Shutter Mode (Long Exposure)” on Continue/Trigger Shutter Mode Selection at
Standard tab through the control software (CLCtrl2).
2. Select
”[0H] FIL_TRG/LVAL/FVAL_TRG_IN” on SP Pin Signal Selection at SP_Pin tab.
3. Input the trigger signal through Pin2. For further details, please refer to section:
SP Pin Signal Selection Table
Pin No
5
4
3
2
Addr=F0 SP1
SP2
SP3
SP4
0
AfterTrigger FILTER
LVAL
FVAL
Trigger Input
1
F1h.0
F1h.1
F1h.2
F1h.3
7
LVAL
CC1
HIGH in Exposure
FVAL
Others
Reserved
Summary of Contents for CL Series