SENS MicroGenius S2/S4 Technical Manual
49
Address High
Address Low
Name
Description
Units
Scale
376
0x178
377
0x179 Output B AC Line Voltage 1 AC Line 1 Voltage
V
32768
378
0x17A
379
0x17B Output B AC Line Current 1 AC Line 1 Current
A
32768
380
0x17C
381
0x17D Output B AC Line Voltage 2 AC Line 2 Voltage (Not applicable to
single phase chargers)
V
32768
382
0x17E
383
0x17F Output B AC Line Current 2 AC Line 2 Current (Not applicable to
single phase chargers)
A
32768
384
0x180
385
0x181 Output B AC Line Voltage 3 AC Line 3 Voltage (Not applicable to
single phase chargers)
V
32768
386
0x182
387
0x183 Output B AC Line Current 3 AC Line 3 Current (Not applicable to
single phase chargers)
A
32768
388
0x184
389
0x185 Output B Battery Check
Duration
Duration of battery check
Sec
1
390
0x186
391
0x187 Output B Battery Check
Interval
Interval between scheduled
automatic battery checks
Sec
1
392
0x188
393
0x189 Output B Number of
Chargers
Number of chargers detected on
SENSbus, 0 - 30
Num
1
394
0x18A
395
0x18B Output B Redundancy Level Number of redundant output
chargers
Num
1
396
0x18C
397
0x18D Output B Extended Status
Current state of alarm/comms circuit
board (see section 11.5)
bit
1
416
0x1A0
417
0x1A1 Output B Maximum Power Maximum rated power
V/Cell
32768
418
0x1A2
419
0x1A3 Output B Maximum Voltage Maximum rated voltage in x.xx V
V/Cell
32768
420
0x1A4
421
0x1A5 Output B Maximum Current Maximum rated current in x.xxA
A
32768
422
0x1A6
423
0x1A7 Output B Program Float
Setting
Float Cell Voltage used in Program
Mode
V/Cell
32768
424
0x1A8
425
0x1A9 Output B Program Boost
Setting
Boost Cell Voltage used in Program
Mode
V/Cell
32768
426
0x1AA
427
0x1AB Output B Program Mode
Mode callouts for Program Mode
setting (battery type… etc.)
Custom
1
428
0x1AC
429
0x1AD Output B Program Cell
Count
Number of cells set in Program Mode
Cells
32768
430
0x1AE
431
0x1AF Output B Program Temp
comp slope
In 0.xx°C per output volt x -1
°C/V
32768
432
0x1B0
433
0x1B1 Output B Low DC Program Alarm setpoint for low DC (used for
Program Mode setting)
V/Cell
32768
434
0x1B2
435
0x1B3 Output B Low Crank
Program
Alarm setpoint for low Crank (used
for Program Mode setting)
V/Cell
32768
436
0x1B4
437
0x1B5 Output B Low Current
Program
Alarm setpoint for low Current(used
for Program Mode setting)
A
32768
440
0x1B8
441
0x1B9 Output B High DC Program Alarm setpoint for high DC (used for
Program Mode setting)
V/Cell
32768
442
0x1BA
443
0x1BB Output B OVSD Program
Alarm setpoint for OVSD (used for
Program Mode setting)
V/Cell
32768
444
0x1BC
445
0x1BD Output B Batt Discharge
Program
Alarm setpoint for Batt Discharge
(used for Program Mode setting)
V/Cell
32768
446
0x1BE
447
0x1BF Output B Batt End
Discharge Program
Alarm setpoint for End Discharge
(used for Program Mode setting)
V/Cell
32768
448
0x1C0
449
0x1C1 Output B Program Boost
Time Limit
Boost time limit (used for Program
Mode setting)
Hr
3600
450
0x1C2
451
0x1C3 Output B Current Limit
Setting
Current Limit setpoint in % of output
current as a 10 bit value
% Rated
A
32768
452
0x1C4
453
0x1C5 Output B Default Output
Helix Float Time
Helix Float Time
Hr
3600
454
0x1C6
455
0x1C7 Output B Default Output
Helix Refresh Time
Hr
3600