8.2 Downloading and setting SE Touch APP
Inverter running data can be obtained through AE Touch APP which can be
downloaded in mobile phone through Bluetooth communications, for details referring
to
Accessory Module Installation Guide.
You can view & set data through the inverter APP, SE Touch. For
NOTE
details about operation, refer to
Accessory Module Installation
Guide
which
is available for free from http://www.Senergytec.com.
Table 8.2
LED indicator status for common inverter fault
PV
Grid-tied
Communications Warning
light
light
light
light
Grid-tied
●
●/
○
ON
●
○
○
Grid Abnormal
○
○
PV normal
●
○
PV Abnormal
○
○
WLAN/WIFI/RS485
●
●/○
○
communications
Strings Reverse
○
○
●
●
Leakage current abnormal
○
●
○
●
Inverter relay abnormal
○
●
●
●
Insulation Resistance
●
○
○
●
abnormal
Grounding current
●
○
●
●
abnormal
Leakage current HCT
●
●
○
●
abnormal
48