7/8
ANTI-FLOOD PROBE ACCESSORY
(ONLY FOR R-GWR-S-1 HOME AUTOMATION SENSOR)
Using this accessory, which can be ordered at www.seneca.it/prodotti/r-gwr in the accessories section, it is possible
to monitor the presence of water in the rooms where it is placed.
For correct operation, place the probe at floor level with the metal sensors facing downwards.
The procedure for connecting the anti-flooding sensor to the standard home automation sensor is shown below:
Use a Phillips screwdriver and remove the screws as per the battery replacement procedure.
Open the top cover and connect the two-pole male connector (reference 2) to the terminal (reference 1) as shown
in the image;
Close the sensor by replacing the cover with the pre-drilled one supplied with the anti-flooding probe accessory.
Do not overtighten the screws to avoid breaking the cover.
Pairing begins automatically and the Rx led starts flashing.
1
2
SENSOR
PROBE
70 cm
CAUTION
Before using a sensor, it is necessary to set the configuration using the “SETUP” button via web
server. The setting procedure is described in the user manual.
MONITORING OF DOOR AND WINDOW OPENING
To install the sensor follow the procedure below:
1.
Identify the installation point of both the sensor and the magnet (e.g.: door frame, upright, window frame),
evaluate the use of the type 1 or type 2 magnet depending on your requirements and clean the two identified
areas;
2.
Apply the round Velcro patch onto the magnet;
3.
Check it is positioned correctly and, to guarantee it works properly, leave a maximum distance of 10 mm
between the two elements;
4.
Remove the Velcro protection film from both the sensor and the magnet, apply in the two areas identified,
pressing lightly for a few seconds.
Sensor
Type 2 magnet
Sensor
Type 1 magnet