background image

7/8

ANTI-FLOOD PROBE ACCESSORY 

(ONLY FOR R-GWR-S-1 HOME AUTOMATION SENSOR)

Using this accessory, which can be ordered at www.seneca.it/prodotti/r-gwr in the accessories section, it is possible 

to monitor the presence of water in the rooms where it is placed.

For correct operation, place the probe at floor level with the metal sensors facing downwards.

The procedure for connecting the anti-flooding sensor to the standard home automation sensor is shown below:

Use a Phillips screwdriver and remove the screws as per the battery replacement procedure.

Open the top cover and connect the two-pole male connector (reference 2) to the terminal (reference 1) as shown 

in the image;

Close the sensor by replacing the cover with the pre-drilled one supplied with the anti-flooding probe accessory.

Do not overtighten the screws to avoid breaking the cover.

Pairing begins automatically and the Rx led starts flashing.

1

2

SENSOR

PROBE

70 cm

CAUTION

Before using a sensor, it is necessary to set the configuration using the “SETUP” button via web 

server. The setting procedure is described in the user manual.

MONITORING OF DOOR AND WINDOW OPENING

To install the sensor follow the procedure below:

1. 

Identify the installation point of both the sensor and the magnet (e.g.: door frame, upright, window frame), 

evaluate the use of the type 1 or type 2 magnet depending on your requirements and clean the two identified 

areas;

2. 

Apply the round Velcro patch onto the magnet;

3. 

Check it is positioned correctly and, to guarantee it works properly, leave a maximum distance of 10 mm 

between the two elements;

4. 

Remove the Velcro protection film from both the sensor and the magnet, apply in the two areas identified, 

pressing lightly for a few seconds.

Sensor

Type 2 magnet

Sensor 

Type 1 magnet

Summary of Contents for R-GWR-IP-1

Page 1: ...tal analogue input and anti flooding sensor EN MI00549 2 EN 1 8 DOCUMENTATION SENECA s r l Via Austria 26 35127 PADOVA ITALY Tel 39 049 8705355 8705359 Fax 39 049 8706287 For manuals in other language...

Page 2: ...n the product or its packaging shows the product must be surrendered to a collection centre authorized to recycle electrical and electronic waste The module must be repaired and damaged parts replaced...

Page 3: ...cy 863 11 MHz Bandwidth 25 KHz SENSITIVITY Up to 146 dBm MAX RF POWER 14 dBm SENSOR PAIRING Maximum number of sensors that can be paired 32 DIGITAL INPUT ANALOG INPUT COUNTERS DIGITAL INPUT For potent...

Page 4: ...LED of the R GWR gateway stops flashing The procedure for replacing a sensor is given in the user manual WALL MOUNTING To fix the sensors to the wall follow the procedure below R GWR S 1 home automati...

Page 5: ...el they can be recycled We recommend using batteries of the same type inside a device the use of batteries of different types could cause liquid leakage or battery breakage or damage the device in use...

Page 6: ...battery 2 Button used to pair the sensor and force communication with the R GWR control unit 3 Analogue digital input connection terminal 4 Clamp for connecting the additional battery pack It is an O...

Page 7: ...ssory Do not overtighten the screws to avoid breaking the cover Pairing begins automatically and the Rx led starts flashing 1 2 SENSOR PROBE 70 cm CAUTION Before using a sensor it is necessary to set...