TECHNICAL SPECIFICATIONS

STANDARDS

ETSI EN 301 489-1 v.2.2.3

ETSI EN 301 409-3 v.2.1.1

EN 60950

ETSI 300 220-2 v3.2.1

POWER SUPPLY

3 V lithium battery type: 

CR2: R-GWR-S-1 home automation sensor

 

CR123A: R-GWR-IP-1 industrial sensor

To check battery life, see user manual.

CONNECTIONS

Screw terminals, 2-way removable screw terminals, 3.5 mm pitch (*)

Anti-flooding probe connector (R-GWR-S-1 home automation sensor)

(*) With 1.5 mm

max cable section

ENVIRONMENTAL 

CONDITIONS

Operating temperature

Humidity 

Storage temperature

Protection rating

From -25 °C to +70 °C

10% ÷ 90% non condensing.

From -40 °C to +85 °C 

IP20 / IP40

ASSEMBLY

Wall using screws or double-sided tape

RADIO TECHNOLOGY

LoRa ®

FREQUENCY BAND

Frequency band: 863÷865 MHz,

Rated frequency: 863.11 MHz,

Bandwidth 25 KHz,

SENSITIVITY

Up to -146 dBm

MAX RF POWER

+ 14 dBm

SENSOR PAIRING

Maximum number of sensors that can be paired: 32

DIGITAL INPUT / ANALOG INPUT / COUNTERS

DIGITAL INPUT

For potential-free contact

ANALOG INPUT

Entry: 0 ÷ 30 V; precision: 0,5%

COUNTERS

Number of counters: 1; Maximum frequency: 1 Hz

SENSOR FUNCTIONS

R-GWR-IP-1

INDUSTRIAL SENSOR

Temperature detection: -25 ÷ 70°C, Precision: 0.5°C between 5 ÷ 60°C

Moisture percentage detection: 0 ÷ 100%, Precision: 3% between 20 ÷ 80% R.H.

1 analogue/digital input

Analogue input: measurement range 0-30V; Precision: +/- 0.15 V

R-GWR-S-1

HOME AUTOMATION 

SENSOR

Temperature detection: -25 ÷ 70°C, Precision: 0.5°C between 5 ÷ 60°C

Moisture percentage detection: 0 ÷ 100%, Precision: 3% between 20 ÷ 80% R.H.

Anti-tamper button

1 analogue/digital input 

Analogue input: measurement range 0-30V; Precision: +/- 0.15 V 

1 reed relay (to control the opening of compartments and rooms)

1 anti-flooding probe (optional)

3/8

Summary of Contents for R-GWR-IP-1

Page 1: ...tal analogue input and anti flooding sensor EN MI00549 2 EN 1 8 DOCUMENTATION SENECA s r l Via Austria 26 35127 PADOVA ITALY Tel 39 049 8705355 8705359 Fax 39 049 8706287 For manuals in other language...

Page 2: ...n the product or its packaging shows the product must be surrendered to a collection centre authorized to recycle electrical and electronic waste The module must be repaired and damaged parts replaced...

Page 3: ...cy 863 11 MHz Bandwidth 25 KHz SENSITIVITY Up to 146 dBm MAX RF POWER 14 dBm SENSOR PAIRING Maximum number of sensors that can be paired 32 DIGITAL INPUT ANALOG INPUT COUNTERS DIGITAL INPUT For potent...

Page 4: ...LED of the R GWR gateway stops flashing The procedure for replacing a sensor is given in the user manual WALL MOUNTING To fix the sensors to the wall follow the procedure below R GWR S 1 home automati...

Page 5: ...el they can be recycled We recommend using batteries of the same type inside a device the use of batteries of different types could cause liquid leakage or battery breakage or damage the device in use...

Page 6: ...battery 2 Button used to pair the sensor and force communication with the R GWR control unit 3 Analogue digital input connection terminal 4 Clamp for connecting the additional battery pack It is an O...

Page 7: ...ssory Do not overtighten the screws to avoid breaking the cover Pairing begins automatically and the Rx led starts flashing 1 2 SENSOR PROBE 70 cm CAUTION Before using a sensor it is necessary to set...

Page 8: ...orce sending the data packet from the sensor by pressing the pairing button indicated in the sensor operation diagram shown on page 6 TROUBLESHOOTING CONTACT INFORMATION Technical support support sene...