MODULE LAYOUT

2/8

Dimensions (LxHxD)

70 x 50 x 25

Weight

45 g

Case

Self-extinguishing UL94-V0 PC / ABS material

Dimensions (LxHxD)

80 x 65 x 45

Weight

150 g

Case

Self-extinguishing UL94-V0 PC / ABS material

LED MEANING

LED

STATUS

LED meaning

Tx (Red)

Flashing

Transmission of radio packets to the R-GWR gateway

Rx (Green)

Flashing

Reception of radio packets from the R-GWR gateway

80 mm

45 mm

65 mm

70 mm

25 mm

50 mm

WARNING

: The full content of this manual must be read before any operation. The module must only be used by 

qualified electricians. Specific documentation is available via QR-CODE shown on page 1.

Electrical and electronic waste disposal (applicable in the European Union and other countries with recycling).

The symbol on the product or its packaging shows the product must be surrendered to a collection centre 

authorized to recycle electrical and electronic waste.

The module must be repaired and damaged parts replaced by the Manufacturer. The product is sensitive to 

electrostatic discharges. Take appropriate measures during any operation.

PRELIMINARY WARNINGS

The word 

WARNING

 preceded by the symbol   indicates conditions or actions that put the user's safety at risk.

The word 

ATTENTION

 preceded by the symbol 

 indicates conditions or actions that might damage the 

instrument or the connected equipment. The warranty shall become null and void in the event of improper use or 

tampering with the module or devices supplied by the manufacturer as necessary for its correct operation, and if 

the instructions contained in this manual are not followed.

N.B: THE LEDS, IN BOTH SENSORS, ARE PLACED INSIDE THE BOX. THEY ARE NOT VISIBLE FROM THE OUTSIDE. 

Summary of Contents for R-GWR-IP-1

Page 1: ...tal analogue input and anti flooding sensor EN MI00549 2 EN 1 8 DOCUMENTATION SENECA s r l Via Austria 26 35127 PADOVA ITALY Tel 39 049 8705355 8705359 Fax 39 049 8706287 For manuals in other language...

Page 2: ...n the product or its packaging shows the product must be surrendered to a collection centre authorized to recycle electrical and electronic waste The module must be repaired and damaged parts replaced...

Page 3: ...cy 863 11 MHz Bandwidth 25 KHz SENSITIVITY Up to 146 dBm MAX RF POWER 14 dBm SENSOR PAIRING Maximum number of sensors that can be paired 32 DIGITAL INPUT ANALOG INPUT COUNTERS DIGITAL INPUT For potent...

Page 4: ...LED of the R GWR gateway stops flashing The procedure for replacing a sensor is given in the user manual WALL MOUNTING To fix the sensors to the wall follow the procedure below R GWR S 1 home automati...

Page 5: ...el they can be recycled We recommend using batteries of the same type inside a device the use of batteries of different types could cause liquid leakage or battery breakage or damage the device in use...

Page 6: ...battery 2 Button used to pair the sensor and force communication with the R GWR control unit 3 Analogue digital input connection terminal 4 Clamp for connecting the additional battery pack It is an O...

Page 7: ...ssory Do not overtighten the screws to avoid breaking the cover Pairing begins automatically and the Rx led starts flashing 1 2 SENSOR PROBE 70 cm CAUTION Before using a sensor it is necessary to set...

Page 8: ...orce sending the data packet from the sensor by pressing the pairing button indicated in the sensor operation diagram shown on page 6 TROUBLESHOOTING CONTACT INFORMATION Technical support support sene...

Reviews: