4/8
PAIRING PROCEDURE
1.
The R-GWR device can be paired with a maximum of 32 sensors.
2.
A paired sensor is enabled for data exchange with the Gateway.
3.
To pair one or more new sensors it is necessary to follow the procedure below:
4.
5.
Power up the R-GWR gateway and the radio sensor
6.
In the gateway press the “START NEW SENSOR PAIRING” button in the “Status” section of the web server.
7.
The STS LED of the gateway will start flashing.
8.
In the sensor you want to pair, press and hold the pairing button until the red LED lights up (transmission).
9.
If the green LED of the radio sensor (radio reception) lights up, the association was successful and the new
sensor with its data will appear in the “Status” section of the R-GWR gateway web server.
10.
Press the pairing buttons of each sensor you want to pair as in the previous point
11.
Once all the sensors have been paired, press the “STOP NEW SENSOR PAIRING” button in the R-GWR
web server “status” section.
12.
The STS LED of the R-GWR gateway stops flashing.
The procedure for replacing a sensor is given in the user manual.
WALL MOUNTING
To fix the sensors to the wall follow the procedure below:
R-GWR-S-1 home automation sensor:
Use a Phillips screwdriver and remove the screws (reference 1 and 2 shown on page 5);
Use a Phillips screwdriver and remove the PCB fixing screw (if the battery is installed, remove the battery in order
to reach the PCB fixing screw);
Remove the PCB, taking care not to damage it;
Use the holes on the bottom of the sensor as references to drill the support;
Insert the supplied dowels;
Fix the sensor base with the supplied screws;
Reposition the printed circuit and fix it with the previously removed screw;
Replace the cover and tighten the screws firmly all the way.
R-GWR-IP-1 industrial sensor:
Use a Phillips screwdriver and remove the screws (reference 1 and 2 shown on page 5);
Use the holes on the bottom of the sensor as references to drill the support;
Insert the supplied dowels;
Fix the sensor base with the supplied screws;
Replace the cover and tighten the screws firmly all the way.
R-GWR-IP-1 industrial sensor:
R-GWR-S-1 home automation sensor: