SL320003270 Ed 03_EN
22
Extract the product suction tube by carefully removing it from
the peristaltic pump.
- Pull the inlet pipe subjection (A) to the left and extract the
connection racor (B) from the inlet pipe (C).
- Remove the used pump tube (G) from the valve connection
pipe.
- Extract the air flow regulator (E) and the air inlet valve (F)
from the pump tube.
2) - ASSMEBLE A NEW PRODUCT SUCTION TUBE ON
THE MACHINE
- Assemble in the suction tube, the pump tube the air inlet
valve (F) and the air flow regulator (E).
.
- Lubricate the connection racor O-ring (B) with vaseline. Pull
the subjection (A) to the left and introduce the connection racor
(B) in the inlet pipe (C). Release the subjection (A) in order to
block the connection racor (B).
- Introduce the product suction tube carefully into the peristaltic
pump. The tube must not be twisted, too tense or pressed
against the pump's compression rollers. Make sure that the
tube is positioned in the centre of the compression rollers and
close the lid of the pump.
-Replace the fridge top tray
Before using the machine with the new pump
tube kit it is necessary to perform its running in
(se cap. 7.6)