SL320003270 Ed 03_EN
16
Remove any possible product residue from the tap body and
dismantle it as follows:
- using the lever (G),raise the plunger (H).
- remove the O-ring and the tap pin (I) that block the lever (G).
- remove the lever (G).
- remove the plunger from its place (H).
- remove the tap body bolt (L).
- remove the rest of O-rings.
7.1.3 Agitator disassembly
Remove the agitator from its place inside the cylinder, taking
special care not to hit off the cylinder wall.
Remove the drive shaft seal by slindingalong the length of the
shaft.
7.1.4 Disassembly of product suction tube
To remove the product suction tube, proceed as follows:
- Remove the fridge top tray from inside the fridge. Press the
tray retainer and remove it pulling downwards.
- Open the peristaltic pump by opening its lid.
.
Extract the product suction tube by carefully removing it from
the peristaltic pump.