User and settings manual
20
OPERATION MODE SELECTION
In group
“OPERATION MODE”
select the required controller operation mode. You can select
between automatic mode, controller switch-off and manual mode.
Description of operation mode:
You choose the required mode by pressing buttons , and confirm it by press-
ing button .
You exit the setting by pressing button .
Manual mode
This mode is used for testing the heating system or in case of a malfunction.
Every output can be manually activated or deactivated.
By pressing buttons and ,
move through move among individual out-
puts R1-R6*. Select the output of which
state you want to change by pressing the
button. Values ON, OFF, AUTO or pump
RPM 40 %, 55%, 70 % and 85 % will begin
to flash. Now you can change the output
status with buttons and .
Confirm the selection by pressing the
button.
Exit the setting by pressing the button.
Controller switch-off
Controller is not performing system control and switches off all outputs.
All temperatures are still measured and shown. Protection functions are still
active and able to switch on output.
Automatic operation
Heating is active.
In the automatic operation mode, the controller enables activation and deacti-
vation of additional energy sources (for example: oil boiler, heat pump, electric
heater, etc.).
To activate or deactivate additional sources, select the icon again,
when the automatic operation mode has already been selected. A new screen
with additional sources will appear, where you can move through sources with
buttons and . By pressing the button,
select the source you wish to activate or deactivate. Symbol or will
begin to flash. You can change the source status with buttons and .
Exit the setting by pressing the button.
* Depends on model of controller.
Summary of Contents for SGC36
Page 2: ......
Page 4: ......
Page 137: ...137 TABLE 1 Factory settings of parameters P1 TABELLE 1 Werkseinstellungen vom Parametern P1...
Page 138: ...138 TABLE 2 Factory settings of parameters P2 TABELLE 2 Werkseinstellungen vom Parametern P2...
Page 139: ...139 TABLE 3 Factory settings of parameters P3 TABELLE 3 Werkseinstellungen vom Parametern P3...
Page 141: ...NOTES NOTIZEN 141...
Page 142: ...NOTES NOTIZEN 142...
Page 143: ......