SR-1800
6
Rotary Switch RSW2 Settings
CAUTION
· Be careful when configuring settings. Malfunction will occur if settings are incorrect.
· Make sure the power is off when configuring settings.
Set the paper weight to match the sheet to be used. This setting is used for double feed
detection.
Reference: ”Reading Sheets” (P.32)
: Indicates the factory settings.
SW No.
Paper weight
Paper weight
0
Double feeding detection disabled
-
1
72kg (84g/m
2
) OCR paper
(0.11mm)
2
90kg (105g/m
2
) OCR paper
(0.13mm)
3
110kg (128g/m
2
) OCR paper
(0.15mm)
4
135kg (157g/m
2
) OCR paper
(0.18mm)
5 to 9
Not used
-
Double Feeding:
The device’s automatic sheet supply has a detection function to inform of an error when
double feeding has occurred.
The double feeding detection function uses a transmission-type sensor to determine whether
double feeding has occurred by the difference in the amount of transmitted light due to the
thickness of the sheet.
Set the double feed detection according to the thickness of the sheet being used.
Settings are configured using the rotary switch RSW2, with a factory setting of 90kg (RSW2-
2).
CAUTION
Depending on the paper quality and printing, the device may detect a double feed error
when only one sheet passes through. In such a case, try increasing the setting value by one
level.
eg: If double feed error occurs with RSW2 set at “2” (90kg), select “3” (110kg).