REMOTE CONTROL DIP SWITCHES
WARNING: Do not alter DIP switches 1
to 8 on top row and 7 & 8 on bottom row
as the cooler will cease to work.
Record the dip switch settings for this cooler
below (if applicable)
Definition of DIP switch positions (first 6 in
bottom row only) are as follows:
(1)
Reserved for later use.
(2)
OFF, 24 hour clock.
ON, 12 hour clock.
(3)
OFF, 1.0, 3/4HP Motor.
ON, Not Used
(4)
OFF, no pre-cool.
ON, pre-cool.
(5)
OFF, drains 3 days after power
off.
ON, drains 3 hours after power
off.
(6)
OFF, drains every 65 minutes of
operation.
ON, activates water salinity circuit
(WaterManager).
ILL217-H
ON
ON
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
OFF
OFF
EXAMPLE ONLY
Cooler level and secure.
All roof work properly sealed.
Ductwork and air distribution checked and outlets correctly set.
Signed by Installer:
…………………………………………………
Dated:
………………………………………………………………
All wiring complete.
Control switch correctly installed.
Motor and pump correctly plugged into sockets.
Drain/overflow fitting correctly installed.
Water level and float adjustment checked.
Pump runs and water evenly distributed to all cooling pads.
All control functions checked.
Owner instructed on correct operating procedure and supplied with
operating instructions.
SERVICE ENQUIRIES:
Contact your local Dealer or Installer for
assistance.
Owners Name:______________________
__________________________________
Telephone:_________________________
Address:___________________________
__________________________________
__________________________________
Dealer:____________________________
__________________________________
Installer:___________________________
__________________________________
Date Installed:_______________________
Model No.:__________________________
Serial No.:__________________________
Motor Type:_________________________
Motor Power:_________________________
1
18
Installation Checklist
19
EXV Evaporative Cooler