9
Press
or
to select your desired delay
time.
4.
Press
to set your selection.
At any time when the wall control is OFF, you can
manually drain the cooler by pressing and holding
and
for 1 second. The display will show
“
dr
”
to
confirm the operation has activated.
Note that some regulating authorities require servicing to
be conducted at specific intervals.
•
Turn off the power supply to the air cooler.
•
Turn off the water supply to the air cooler.
•
Remove the pad frames as shown. (Fig. B)
DRAIN MODE
WARNING! If the supply cord is damaged, it must be
replaced by a special cord available from the
manufacturer or it
’
s service agent.
END OF SEASON SERVICE
MAINTENANCE
WARNING! Maintenance must be carried out by an
authorized service agent. Power to the cooler must
be disconnected before pad frames are removed or
you may risk personal injury.
HEALTH REGULATIONS
•
Turn off power switch inside the cooler.
(Fig. A)
•
Check and clean the lid water spreaders
(Fig. C)
•
Thoroughly clean the tank and pump filter.
•
Gently wash the pads to remove any dust.
•
If freezing conditions can occur at any time, a
drain down facility must be provided at the lowest
point of the water supply pipe.
•
Re-fit the pad frames.
•
Turn off the main power supply to the air
cooler
•
Remove the pad frames as shown.
•
Ensure the power switch in the cooler is off.
•
Gently wash the pads to remove any dust build up
during the winter period. If the pads are in poor
condition, replace them.
•
Turn on the power switch inside the cooler.
•
Turn on the water and then the main power.
•
Re-fit the pad frames and run the cooler.
To remove a pad frame, insert a flat screw driver tip into
the slot as shown and lever until disengagement occurs.
Take hold of the pad frame and pull it towards you until
the internal side clips disengage. Pivot the pad frame
outwards and lift up. Take care not to damage the pad.
Repeat these steps for the remaining pad frames. (Fig.
B)
PRE SEASON SERVICE
IMPORTANT! Do not damage the pads with high
pressure water spray.
REMOVAL OF PAD FRAMES
The pads supplied have been selected to give the
highest possible cooling performance. WHEN
REPLACING PADS DO NOT USE ALTERNATIVES.
The manufacturer is not responsible for the
performance, damage to, or safety of the air cooler
when alternative pads are used. Using poor quality
or incorrect pads may cause water carry-over that
might enter electrical components creating an
electric shock or fire hazard.
Drain Delay Time
Display Number
00
01
02
03
04
4 hours
1 Day
2 Days
3 Days
4 Days
STANDARD
A
ILL187-E
1
2
3
B
ILL1383-A
C
5
SEELEY INTERNATIONAL –
INSTALLATION & OPERATION MANUAL
10
Using the
Wall Control
SENSOR
TOUCH
SENSOR
T
OUCH
W
allControl