TIMED AUTOMATIC STOP
USING THE COOLER
AIR TOO COLD
AIR NOT COLD ENOUGH
You can also set the air cooler so that it will turn off after a
set number of hours.
1. To set a delayed stop time, press
with the cooler
.
”
Stopping in
”
will display.
2. Press
or
to adjust the number of hours
before the air cooler will stop. The maximum delay
setting is 24 hours.
3. Press
again to begin the timed stop.
Now that you have read these instructions, press the
button to turn your air cooler on. If the air cooler
has not operated for a while
“
Preparing to Start
”
will flash
on the display (see page 7). The pre cool cycle will begin
and will take only a few minutes to complete. After this
time, the fan will start automatically, and you can enjoy
the comfort of cool fresh air!
With the cooler running in Automatic mode, you may find
that you are too cold or that the air cooler is blowing too
much air. Press
to reduce the amount of cooling.
If you are too cold with the cooler running in Manual
mode, then press
to reduce the fan speed. You
can also circulate fresh uncooled air by pressing
until
“
Vent
”
displays.
You may find that with the air cooler running in Automatic
mode, you are not cool enough. Simply press
to
increase cooling.
If you are not cool enough with the air cooler running in
Manual mode, then press
to increase the fan
speed. Ensure that cooled air is circulating by pressing
until
“
Cool
”
displays.
You can experiment with the settings on your wall
control. This is the best way to decide what suits your
needs.
RUNNING
DRAIN VALVE
This air cooler is supplied with an automatic drain that
performs two primary functions:
1. It opens and closes automatically to control salt
concentrations in the tank.
2. It opens to drain all water and keep your tank dry
during prolonged
“
off
”
cycles.
Your cooler will automatically change some of the water
during operation when the water salinity becomes too
high. This ensures the water is always fresh and helps
maintain your cooler in good condition to ensure
optimum cooling performance. This is called
“
salinity
sensor
”
method. Alternatively and if necessary, the air
cooler can be set to change some water after a set time
of cooling operation. The frequency of the automatic
drain function may have been adjusted by your installer.
This is called
“
timed drain
”
method.
You can select either method of water replacement with
the following steps.
1. When the cooler is
, press and hold
.
2. While still pressing
, press
.
3. A number will display which corresponds to the
selected salinity control method as shown in the
table below.
Press
or
to change the displayed number
to the desired salinity control method.
4.Press
to set your selection.
When the air cooler is not operated for 72 hours, the
drain valve will open automatically to empty all water
from the cooler. If necessary, you can adjust this delay
time with the following steps.
1. When the cooler is off, press and hold
.
2. While still pressing
, press
.
3. A number will display indicating the current water
drain delay time according to the table.
OFF
ILL1119-A
Display Number
Salinity Control Method
00
01
Salinity Sensor
Timed Drain
STANDARD
SENSOR
T
OUCH
W
allControl
9
EXV Evaporative Cooler
SENSOR
T
OUCH
W
allControl
Using the
Wall Control
SENSOR
TOUCH