16
|
INTERNATIONAL
Within the SETTINGS menu of the MagIQtouch Controller is the
COOLER sub-heading. Here various settings of the cooler can
be adjusted.
About Appliance
Displays information such as model number, serial number and
software version for all coolers connected to the controller.
Night Quiet Mode
Restricts fan speed to a specified level during a specified night
period.
Manual Drain
Turns cooler off and drains the tank.
Pad Flush
Turns cooler off and runs pump for a specified amount of time.
Auto Restart
By turning this option to ‘ON’, the cooler will automatically
restart after a power failure.
Drain and Dry
Cooler will drain and fan will run for 1 hour every day at a
specified time.
Water Manager
Select the preferred water management method:
•
Salinity Measurement - replaces water when salinity level
reaches set point.
•
Timed Drain - drains the tank after 8 tank fill cycles or every
65 minutes (system dependant).
•
No Drain Control - salinity control external to electronics eg.
continuous bleed.
•
No Water Thermostatic - allows thermostatic control in VENT
mode. No water present. Cooling performance is limited.
AutoWinterseal™ Open Speed
The cooler fan will turn on at the specified weather seal opening
speed for the first 10 seconds each time it starts up. It will then
return to the set fan speed.
Pre-wet
When COOL mode is activated, the pump will run for 90
seconds before the fan is switched on.
Salinity Level
Sets the salinity level at which the tank will drain in “SALINITY
MEASUREMENT” mode.
Tank Drain Delay
Sets the time delay before the drain valve opens after the pump
in the cooler is turned off.
Autostart
Automatically restarts the cooler in the last operating mode after
a power outage.
ILL1664-A
ADJUSTING COOLER SETTINGS
COMMISSIONING COMPLETION CHECKLIST
cont
POWER
□ REGULATIONS - The power supply adheres to all local and
national regulations and is wired back to the distribution board
on its own separate circuit.
□ CHECK CABLES - Cables have been correctly connected to
the control boxes:
□
Power supply
□ Motor cable(s)
□
Control cable
□
Drain valve
□
Solenoid cable
□
Pump cable
□
Probe cable
□ OWNER INSTRUCTIONS - The owner has been instructed
how they can electrically isolate the unit at the meter box in
case of an emergency.
DUCTWORK
□ NO LEAKS - All ducts are hung correctly and there are no air
leaks.
□ CONTROLLER SEALED - All wall holes behind the controller
have been sealed.
□ QUIET - Check that the cooler runs quietly and with an even
distribution of air to all outlets.
□
AIRBALANCE – The air balance for all outlets has been
adjusted to the customer’s satisfaction.
FLUSHING CHILLCEL PADS
□ PADS FLUSHED - To prevent initial start-up odours from the
cooling pads, it is a requirement to flush water through them
and drain the tank. Operate in COOL mode, lowest speed
for 5 minutes, then drain the tank. Repeat several times if
necessary.
FINAL TEST
□ Once you are satisfied that the cooler is installed and
commissioned correctly, run the cooler and ensure that
everything is working as it should.
CUSTOMER HANDOVER
□
Principles of Ducted Evaporative Cooling explained.
□
How far the windows need to be opened.
□
How to turn the cooler on.
□
How to operate the controller.
□
How to drain the cooler.
□
How to turn the power and water off.
□
Maintenance requirements.
□
The customer has been given the Owner’s Manuals &
Warranty Card.
CLEAN-UP
□
All the installation rubbish has been removed and, if
applicable, any property damage repaired. Your aim should
be to have the customer not even be aware that you have
been on site.
FINAL CHECK
□
With all side panels in place and the unit running for a short
period in cooling mode, ensure all pads have even water
saturation and there are no visible water leaks