12
|
INTERNATIONAL
ILL1062-G
For LCQ, LCS, TBQ, TBS, BMQ & CPQ coolers
Connect the water sensor plug (D) and inlet solenoid plug (C)
as shown.
Route the pump cord as shown.
Once the water level is set correctly, isolate the electronics
module and connect the pump plug (F).
Important!
Do not connect the pump plug until the water level
is set.
WARNING!
Do not run the pump while the pad frames are off
and the fan is on.
Once plugs are connected, switch the electronics module on.
Important!
Ensure the flexible splash protection cover is in place.
ILL1061-C
ILL1095-B
LEGEND
A - Control Cable
B - Speed Adjustment
C - Inlet Solenoid
D - Water Sensor
E - Drain Valve
F - Pump
G - Operation & Fault
code LED’s
Ensure the cables cannot rest in the water once the tank is filled
and plugs are connected in the correct orientation.
ILL1075-C
Route the drain valve cable as shown before connecting it to
the electronics module (E).
Refer to the installation manual provided with the MagIQtouch
Controller for instructions on installing the controller. The wall
control cable plugs into the electronics module - (A) (refer
diagram adjacent). Coolers are supplied with a 20m (66’)
control cable. Longer cable lengths are available from Seeley.
Important!
The maximum cable length allowed from the
MagIQtouch Controller to the first cooler is 25m (82’). For any
additional coolers added into the system with a link module the
maximum allowed length is 40m (131’). Therefore, failure of the
product or components to operate correctly due to modification
to supplied
cables, or the use of non-approved cables will NOT
be accepted under the Manufacturer’s Warranty.
We have this cable available through our Sales order office and
spare parts outlets in the following lengths:
ELECTRICAL CONNECTION
cont
Part No. Length Details
833880
20m
MagIQtouch Controller Cable (No Ferrite)
823553
20m
MagIQtouch Controller Cable (With Ferrite)
862873
1.5m
MagIQtouch Controller Cable (No Ferrite)
861265
3m
MagIQtouch Controller Cable (No Ferrite)
864396
30m
MagIQtouch Controller Cable (With Ferrite)
864402
40m
MagIQtouch Controller Cable (With Ferrite)
CONNECTING THE MAGIQTOUCH /
MAGIQCOOL CONTROLLER
®
CONNECTING THE WATER PUMP
ILL1678-A
DRAIN
MOTOR
CONTROL
WATER
PROBE
PUMP
SOLENOID
WALL CONTROL
DIAGNOSTIC
LEDS
FUSE
MAINS
CONNECTOR
MOTOR
560885
(UNDERSIDE OF ELECTRONICS MODULE)
PUMP
MOTOR
Note!
Fit either the shorting plug or water sensor as required.
For LCQI, TBQI & TBSI coolers
The plug connection points differ from LCQ, LCS, TBQ, TBS,
BMQ & CPQ models.