background image

Release Version 1.2 

 

Please read this user’s manual thoroughly prior to the use this unit for its easy and convenient 
use. 

Caution  (If  you  do  not  keep  any  of  the  below  guidelines,  you  may  get  seriously 
injured or cause somebody’s death) 

■  Please make sure to install this product after unplugging power plug. Also, do NOT use this 

product by connecting many power plugs simultaneously. 

- It may cause abnormal heat, fire or electric shock. 

■  Do NOT leave this product at any place that water falls or splashes. Also, do NOT put 

anything, which is full of water such as a flower vase, on this product. 

- It may cause the malfunction or fire of the product if liquid goes into it. 

■  Do NOT open the product case randomly, disassemble, repair or remodel this product on 

your own because there is some high voltage parts. 

- It may cause fire, electric shock or injury due to abnormal operation. 

■  Do Not install this product at a place where there is high humidity, dust or soot. 

- It may cause electric shock or fire.   

■  Please keep the installation place clean and wipe the place with a dry towel. Also, do NOT 

use water, thinner or organic solvent. 

- It may cause damage on the product surface and may cause product problem or electric shock. 

■  Please leave this product at a cool place which does not have direct rays of the sun, keep the 

temperature optimal in the installation place, and leave the installation equipment or tools 
far away from where is crowded. 

- It may cause fire. 

■  Be careful of the danger that may be caused at humid floor, ungrounded power extension 

cable, worn-out power cord, lack of safety ground connection. If any problem is found, 
please contact where you purchased this product. 

- It may cause fire or electric shock. 

■  Please keep at least 15 Cm for the back of this device from the wall and keep at least 5Cm 

for the sides of this device from the wall. Otherwise, the cables may be bent and/or cut due 
to the narrow space between the device and the wall, and may cause malfunction or fire. 

- It may cause fire, electric shock or injury. 

■  In case of the input voltage for the operation of this device, the voltage fluctuation must be 

within 10% of the rated voltage and the power outlet must be grounded. In addition, the 
power outlet for this device shall not be used for other electric heating appliances such as 
hairdryers, irons, refrigerators, etc. 

- It may cause abnormal overheat, fire or electric shock. 

■  When thundering or lightning, please unplug the power plug for your safety. 

 

Caution  (If  you  do  not  keep  any  of  the  below  guidelines,  you  may  get  seriously 
injured or loss of property.) 

■  Do NOT install this product at where is exposed to strong magnetic or radio waves (RF) and 

adjacent to wireless devices such as radio or TV, etc.

   

■  Do NOT install this product at where has too high or low temperature or humidity. 

Precaution and Safety Guidelines

 

Summary of Contents for SC-16MHD

Page 1: ...Release Version 1 2 16 Channel video input HD analog splitter SC 16MHD User s Manual ...

Page 2: ...rature optimal in the installation place and leave the installation equipment or tools far away from where is crowded It may cause fire Be careful of the danger that may be caused at humid floor ungrounded power extension cable worn out power cord lack of safety ground connection If any problem is found please contact where you purchased this product It may cause fire or electric shock Please keep...

Page 3: ...f you do not follow this manual you may get electric shock or injury Please put power plug at where is available to be controlled easily When any trouble occurs the power plug shall be taken off for power down Power cannot be shut off completely by using power button of the product only When using this product adjacent to equipment which generates strong radio waves such as radio transceivers walk...

Page 4: ...tor as well as any channel loss 1 2 Features Various video input AHD TVI CVBS Support Loop through output Display video of 16 channels in real time Various split mode 4 6 8 9 10 16 Auto sequence function RS 485 communication port for a remote control Alarm port D SUB 26Pin Input 1 Relay contact Output Display and save the date and time when alarm and signal loss are generated Various video output ...

Page 5: ...t MULTI SCREEN To set video screen split mode The locations of split channels can be changed in the Setup menu Split Screen Full Quad 6 Split 8 Split 9 Split 10 Split 16 Split ESC To terminate sub menus in the menu D pad To move to the relevant sub menu in the menu ENTER To set or check sub menu in the menu MINUS To go to the previous channel or channels available in split mode as well e g When pr...

Page 6: ...t USB To connect with a mouse ALARM OUT Relay contact output To operate a light or an emergency bell by using electric signal when any alarm occurs N O Normal Open The contact point is off Default setting N C Normal Close The contact point is on Please refer to the 5 4 Alarm Input and or 5 5 Alarm Output for more information of alarm DC 12V IN Power input RS 485 RS 485 communication by an external...

Page 7: ...Status Use a mouse for the menu settings Enter the Setup menu to show the following screen Device Name Device ID Date Firmware Firmware version Language Language settings Camera Camera status 4 1 2 Set up Enter System Set up to show the following screen ...

Page 8: ...k OK to save the entered device name Click Cancel not to save the entered device name Device ID Click the numeric pad icon on the right side to display the following numeric pad on the screen and use it for RS 485 related device ID settings Enter any number from 1 to 255 to set up RS 485 device ID Click OK to save the entered device ID and click Cancel not to save the entered values Date Format Se...

Page 9: ...selected item AM PM Hour Minute Second will be marked in blue Change numbers by clicking buttons on the right side Click OK to save the setting values and click Cancel not to save them 4 1 2 3 Firmware Indicate this splitter s software version 4 1 3 Event Enter System Event to show the following screen Event items are as follows System Start System Reboot Setup Default Imported Exported Resolution...

Page 10: ...nging the settings to recognize the video signal again Transparency setting values are adjustable by buttons on OSD menu Video Output Select video output Main Screen Spot Click Apply on the right side to complete the setup Reboot this splitter after changing the settings to recognize the video signal again Some LEDs on the front interface may not be turned on when rebooting and after completing it...

Page 11: ...Set the horizontal interval of OSD icons Range 0 50 Bigger number means more interval Vertical Set the vertical interval of OSD icons Range 0 50 Bigger number means more interval Adjust the range by using buttons 4 2 1 3 Menu Icon Enter Display Menu Icon to show the following screen Select which items will be shown on the screen Icons that will be shown on the left right sides Click All to select ...

Page 12: ...switching time in 9 split screen X10 Seq Set the display switching time in 10 split screen Select the cameras to be added into Auto Sequence mode Non selected cameras will not be in the Auto Sequence mode Set up the display switching time among 3 5 10 15 30 60 seconds in the list Click All to set up the display switching time for every camera at once Click the sequence icon on the OSD menu by a mo...

Page 13: ...screen X10 Seq Set the display switching time in 10 split screen Select the cameras to be added in to the Spot monitor s Auto Sequence mode Non selected cameras will be eliminated from the sequence mode Set up the display switching time among 3 5 10 15 30 60 seconds in the camera list Click All to set up the display switching for every camera at once Close the setup menu move the mouse cursor to t...

Page 14: ...arm In function please do not mark there Click All to change every alarm type at once NO Normally Open The contact sensor is open Factory default setting NC Normally Closed The contact sensor is closed Available to set up the event when generating an alarm by the menus at the right bottom Beep Buzzer out when an alarm is generated Message An alarm message pops up and stay on the screen for around ...

Page 15: ...con in the Alarm in menu to show the keyboard and enter the name Select types of alarm out in the Type item NO Normally Open Relay signal output when the contact sensor is open Factory default setting NC Normally Closed Relay signal output when the contact sensor is closed Available to change the operating time or period of Alarm Out in the Duration item ...

Page 16: ...t or hide all at once Select any specific camera in PTZ menu to change the PTZ setting of the selected camera and show the following on the screen Set up Protocol Baud Rate Date Bit Stop Bit Parity Set up a PTZ camera s menu in the Menu Tour Pattern menus If the OSD entry value is 95 PSET please set the Menu to 95 If the Tour shortcut value is 71 79 PSET please set the Tour to 70 If the Pattern sh...

Page 17: ...ack to the previous split mode Split screen Press the MULTI SCREEN on the front interface or click icon to turn to split screen Auto sequence Press the AUTO SEQUENCE key on the front interface or click icon to set up Auto Sequence mode 5 3 Digital Zoom Select the channel to display in Full screen mode Press the left button of the mouse and drag out the part to zoom in Click the left button of the ...

Page 18: ... Operation Connect the relevant channel s alarm signal line contact signal which does not have electric signal and GND line 5 5 Alarm Out function 5 5 1 Alarm Out port Connect the signal port to COM port and NC or NO Example for Alarm Out ...

Page 19: ...trol communication data format Set up the split screen or others by a RS 485 controller in remote distance Data Length 8 Bit Start Stop Bit 1Bit Parity Bit None Baud Rate 9600 Byte Value Function 1 0xA0 STX Launching data 2 0x16 Device Code 3 0x01 0xFF Address Device ID 4 Data Byte Control Data 5 Check Sum Check Sum Byte2 Byte3 Byte4 ...

Page 20: ...CH Full Display 0XA0 0X16 0X01 0X43 0X5A 44 14CH Full Display 0XA0 0X16 0X01 0X44 0X5B 45 15CH Full Display 0XA0 0X16 0X01 0X45 0X5C 46 16CH Full Display 0XA0 0X16 0X01 0X46 0X5D 47 Multi screen 0XA0 0X16 0X01 0X47 0X5E 48 Menu 0XA0 0X16 0X01 0X48 0X5F 49 Enter 0XA0 0X16 0X01 0X49 0X60 4A ESC 0XA0 0X16 0X01 0X4A 0X61 50 4 Split Display 0XA0 0X16 0X01 0X50 0X67 56 6 Split Display 0XA0 0X16 0X01 0X5...

Page 21: ...Release Version 1 2 20 6 Connection Diagram ...

Page 22: ...VBS The connected cable length should not exceed the recommended transmission distance No video display of HDMI signal Please check if the input video belongs to the supported input video resolutions of SC 16MHD Please check if the input video format and video format setting of SC 16MHD are same Please check the connection status of the BNC connectors of input video Please check if the monitor inp...

Page 23: ... Input and Loop out distance CVBS In CVBS Out 1Vp p 75 Ohm Termination HDMI Out HDMI Cable 3m VGA Out VGA Cable 3m Connection Port VIDEO In BNC F 75Ω Loop through Out BNC F 75Ω CVBS Out BNC F 75Ω HDMI Out A Type VGA Out D SUB 15Pin USB Mouse connection External Input Output Alarm Input 16EA D SUB 26 Pin Output 1EA Relay RS 485 4P LED Indicator Full or split screen Auto Sequence mode Input Power Po...

Page 24: ...eriod we give you free repair service according to the warranty certificate We charge you with the fee of parts and service despite of free warranty service period Any breakage made without care such as Breakage or trouble made by natural disaster Breakage or trouble made by breaking the product guide or manual Breakage or trouble made by wrong power voltage or frequency When you want to reassembl...

Page 25: ...Release Version 1 2 24 MEMO ...

Page 26: ...Release Version 1 2 MEMO ...

Page 27: ...Release Version 1 2 1 MEMO ...

Page 28: ... 2 SeeEyes Co Ltd 503 509 Sunil Technopia 555 Dunchon daero Jungwon gu Seongnam City Gyeonggi Province Korea Zip Code 13215 TEL 82 0 31 730 5831 5834 FAX 82 0 31 777 3512 E MAIL overseas sscctv com http www sscctv com eng ...

Reviews: