XR200-485B User’s Guide Supplement
35
Using the Panic Zone Test
1. Access the User Menu.
2. Press COMMAND until
SYSTEM TEST?
displays.
3. Press any Select key. The keypad displays
SYSTEM PANICS.
4. Press the Select key below
PANICS
.
5. The Panic Zone Test begins automatically and the keypad
displays
TRIPS: END.
During the Panic Zone Test, trip each panic zone (or button)
on the system by pressing and holding the panic for 1 to 2
seconds.
Note:
You do
NOT
have to hold the panic for 2 seconds in normal
mode. You are only required to hold the panic during the
Panic Zone Test because the zone takes a little extra time to
report when the system is in test mode.
Each time you trip a panic zone, the display number increments
and the keypad buzzer sounds for two seconds.
The number of panic zones tripped is constantly displayed
until the test is ended or no panic zone activity has occurred
for 20 minutes.
6. Press the Select key below
END
to stop the Panic Zone Test.
7.
PANIC TEST OKAY
is displayed when the Panic Zone Test is
completed and all zones tested OK.
8. When the Panic Zone Test ends and a zone failed (did not trip)
during the test, the keypad displays the zone name and
number and the buzzer sounds for one second. Press the
COMMAND key to display the next failed zone.
Note:
During the Panic Zone Test, any zones that fail are not sent
to the receiver or to the pager.
Testing your system’s burglary protection
The System Test function should be a part of your weekly testing
and should be followed by placing the burglary devices in Zone
Monitor mode. This allows you to open and then close each
protected door and window while listening for the keypad to beep
confirming its operation. See Zone Monitor.
Bank Safe & Vault
Areas of your system may be programmed for Bank Safe & Vault to
prevent anyone from disarming an area outside of its scheduled
open period. Any zones in the area cannot be bypassed or force
armed at arming. This operation provides added security to safe
and vault areas of your system. Also, zones assigned to bank safe
and vault areas may not be bypassed at arming.