Doc. No.: A05280692 Rev. AE ECO: 13200 Date: 11/04/2019
68
The ID Exit Panel has been initialized and all memory has been erased. Reprogram and enable PM
Mode feature.
The PM Mode feature has been disabled (turned off). Refer to
Section 9
of this manual to enable PM
Mode.
The ID Exit Panel may have been programmed incorrectly. Reprogram for the correct times.
Daylight Savings Time: Reprogram the ID Exit Panel.
Symptom 15:
The ID Exit Panel is in PM Mode and armed, but when the door is opened the alarm does
NOT sound.
Potential causes and corrective actions
:
Check the magnetic door contacts for proper operation: Open loop when the door is open and closed
loop when the door is closed.
If the magnetic door contacts are working properly, the problem may be in the panel. Replace the ID
Exit Panel.
Symptom 16:
The ID Exit Panel has been working properly. Now the system seems to have short range.
Potential causes and corrective actions
:
The ID Exit Panel has been initialized and all setting are back to factory defaults.
There may be a loose or broken antenna inside the ID Exit panel. Inspect for physical damage to the
front of the panel. If damage is observed, replace the ID Exit Panel.
Verify that the range adjustment has not been changed. If it has, readjust the range for proper
performance.
SECTION 12 TROUBLESHOOTING
Summary of Contents for KinderGUARD ID
Page 8: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 8...
Page 9: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 9...
Page 10: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 10...
Page 75: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 75...
Page 77: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 77...
Page 78: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 78...
Page 81: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 81...