Doc. No.: A05280692 Rev. AE ECO: 13200 Date: 11/04/2019
27
Data Loop for ID Exit Panel to ID Exit Panel
The communication data loop is daisy chained from ID Exit Panel to ID Exit Panel and connected to the XIU. Run the
wire from ID Exit Panel to ID Exit Panel and to the XIU using the communication wire. Each panel has a CAN bus
interface for the data loop connection. Connect the bare wire to GND, the blue wire to CAN H and the white/blue to the
CAN L. Each panel has a termination jumper (resistor) located next to the CAN bus (this includes the XIU). At each end
of the data loop the CAN bus needs to be terminated (jumper on). All other devices in the loop must have the termination
jumper off.
Secure Care strongly recommends that all wiring used to install Secure Care equipment be run at least
18 inches from all other wiring and not be installed inside metal conduit. It is also strongly
recommended to not utilize cable trays used in networking installations and to keep the wires off of
ceiling grids. If the wiring is installed in any of these manners it could cause undesired induction of
Radio Frequency (RF) interference with our system
.
FI
R
E
PU
SH
DO
OR
EGR
ESS
LO
CK
A
U
X
SECURE CARE
PRODUCTS
A
U
X
LO
CK
-
+
NO
C
NC
NO
C
NC
NO
C
NC
NO
C
NC
+
-
KEY
PAD
O
N
1 2
3 4
1
2
3
4
1 2
3
4
5
6
7
GND
CAN H
CAN L
FI
R
E
PU
SH
DO
OR
EGR
ESS
LO
CK
A
U
X
SECURE CARE
PRODUCTS
A
U
X
LO
CK
-
+
NO
C
NC
NO
C
NC
NO
C
NC
NO
C
NC
+
-
KEY
PAD
O
N
1 2
3 4
1
2
3
4
1 2
3
4
5
6
7
GND
CAN H
CAN L
Communication
Termination Jumper
CAN Bus
Interface
Bare wire
Drain wire for shield
Bare wire
Blue wire
White/blue wire
Blue wire
White/blue wire
To XIU or
another
Exit Panel
Figure 9-6 Data Loop for ID Exit Panel to XIU Connection
SECTION 9 INSTALLATION AND CONNECTIONS
Summary of Contents for KinderGUARD ID
Page 8: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 8...
Page 9: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 9...
Page 10: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 10...
Page 75: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 75...
Page 77: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 77...
Page 78: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 78...
Page 81: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 81...