ProLogic L02-C
Operation Instructions
27
Time Delay, if programmed previously, remains active.
10.3 Mechanical Reset
SecuRam Safe Locks can operate in either Analog mode or Digital mode. When they are paired with the
SafeLogic Series (EntryPads with no LCD screen or fingerprint reader) the safe lock operates in analog
mode.
When paired with a ProLogic Series (EntryPads with an LCD screen) or ScanLogic (EntryPads with a
fingerprint reader and/or LCD screen), the safe lock operates in digital mode.
The ProLogic L02-C is a digital system and can be paired with any SecuRam safe lock body.
Note: The pairing of the StrikeBolt and the ProLogic L02-C EntryPad is not UL listed.
If the lock body that you are pairing the ProLogic L02-C with has been paired previously with an analog
system, for example the SafeLogic Basic (or any other SafeLogic Series EntryPad)or was set at the factory
in the default Analog mode, the following Mechanical Reset procedure must be followed:
Step 1: Ensure that the EntryPad is not connected to the lock, and that the battery is connected
to the EntryPad.
Step 2: Find the reset hole on the back of the lock (under the QC sticker).