11
M00 Control Panel
No entry delay
No
Short programming manual - basic information
Intruder alarm system
System with
KM24, KM24A
, KM24G keypads
PARTITIONS
MODULES
Partitions allow you to break up a large area into smaller sections. This feature is useful to disarm certain areas while leaving other areas
armed, or to limit access of certain areas to other users.
Control panel
PAS808M
support
s
up to 7 modules
and
control panels
PAS8
16, PAS832, P16, P32, P64
supports up to 15 modules.
P01 Apartment
1
Name
Apartment
Service Mode
}
System Setup
}
Modules
}
Module settings
It is recommended to give an appropriate name to a partition. The system will use it
when sending
SMS or
when
show
ing
status of the partition on keypad's LCD.
For next character possition press [
]
or [
‚
] key.
Move the
cursor on the wrong character to delete it and press [0].
2
P01 Apartment
In Use
Yes
The alarm system can be divided into 4 partitions for operating flexibility.
Confirm the activation of
a
new
partition by selecting
Yes
. Press
[
Ü
]
or [7] for the next partition.
Exit Delay
time can be different for each partition in control panels PAS816v3, PAS832v3, P16, P32,
and
P64.
3
P01 Apartment
Exit Delay
30 sec
4
P01 Apartment
No entry delay
No
This setting changes entry delay time in partition to 0 seconds (excluding PAS808M). User should remotely
disarm the system before entering partition.
3
P01 Apartment
Arming timer
[ENT]
3
P01 Apartment
Pre-Alarm timer
[ENT]
In this menu it is possible to assign the timer(s) to partition. Auto-arming starts at a specific time of day and arms
the partition in
Stay
mode. Auto-arming will be aborted if any of the zones in partition will be violated or trouble
will appear during exit delay. Use
the
[ENT] key to
access
the
menu, then press [#] to assign
a
timer to
the
partition. Save changes by pressing the [ENT] key.
Note:
if you see dashes (---) instead of [ENT], it means that
no timers are programmed in the system (program system timers in the menu:
Main menu
}
S
ettings
}
Timers
).
In this menu it is possible to assign the timer(s) to partition. Auto-arming starts at a specific time of day and arms
the partition in
Pre-Alarm
mode. Use
[ENT] key to
access
menu, then press [#] key to assign
a
timer to
the
partition. Save changes by pressing the [ENT] key.
Note:
if you see dashes (---) instead of [ENT], it means that
no timers are programmed in the system (program system timers in menu:
Main menu
}
S
ettings
}
Timers
).
M00 Control Panel
1
Name
Control Panel
It is recommended to give an appropriate name to the module. The module name will appear on keypad
’s
LCD if
there will be a
ny
trouble with the module.
2
M00 Control Panel
Address
00
Registered module address is shown in a second row and on the upper-left corner of LCD (eg. M00 = 00
address). Please remember the module address and use it to program zones and PGM outputs.
3
M00 Control Panel
Type
PAS832
Registered module type is shown on LCD. Available module types: PAS816, PAS832, P16, P32, P64,
PWR20,
KM24, KM24A, KM24G, EXT116S, GSV6U, GSVU, EXM800, PROX8, and LAN800.
4
M00 Control Panel
Serial No.
805308385
Registered module serial number is shown on LCD. If you don't see modules serial number, it means that the
module is not registered in the system. See page 2 for more information about manual module registration.
5
M00 Control Panel
Use module tamper
Yes
For additional security it’s recommended to use tamper to protect modules. Tamper can be activated by using:
Z6 - on control panels;
Z1 - on EXM800;
TMP
- on
PWR20
;
back switch - on keypads.
If
Use module tamper
is selected as
No
, then zones Z6 on control panel and Z1 on EXM800 can be used as
regular zone terminals.
Basic settings for all modules:
Extended settings for control panel:
Keypad's screen will show PGM trouble when the load on a preprogrammed PGM output will not be detected by
the control panel. By default PGM load detection is disabled.
7
M00 Control Panel
PGM load detection
No
8
9
10
M00 Control Panel
Cut-off +BELL
Cut-off -PGM(1)
Cut-off +PGM(2)
Yes
Yes
No
Control panel can be programmed to cut-off the PGM output when it detects battery's voltage is approaching a
critical level of discharge
.
The threshold is 11,5V.
This setting changes entry delay time in all partitions to 0 seconds (for PAS808M only). User should remotely
disarm the system before the entering partition.
12
M00 Control Panel
Arm anyway
No
13
M00 Control Panel
EXT116VM count
4
Usually the system stops counting exit delay if system’s zone is violated during the exit delay. If this setting is set
to
Yes,
then the system will continue counting the exit delay and will sound an alarm if any of the zones will be
violated during exit delay.
All virtual wireless modules EXT116VM are usually enabled by default. DO NOT FORGET to run an automatic
module registration if this setting was changed.
Service Mode
}
System Setup
}
Partitions
Page 3