Short  programming manual - basic information 

Intruder alarm system

System with  

KM24, KM24A

, KM24G keypads

Page 11

Security  Settings

This setting allows to enable or to disable access to the special user menu, where installer with his PIN can 
restore 1st user’s PIN to default and the 1st user with his PIN can restore all enabled user PINs to default.

 PIN  resetting

Disabled

5

Security  Settings

 Duress  code

Disabled

6

This feature is intended for situations where the user is forced to disarm or arm the system under a threat. This 
setting enables or disables this feature. Duress code is individual for every system user. Duress code = X1, X2, 
X3, X4 when X4 = X4 + 1 (X1, X2, X3, X4 are digits). Example: user PIN is 123

4

, duress code will be 123

5

.

Note:

 if certain system 

user's A

 duress code matches with another system 

user's B

 PIN code, then the system will use 

user's B

 PIN instead 

of the duress code of 

user A

 to complete the control action. It is recommended to test duress code availability before using the system. The 

event of duress code use will be generated in the event log.

Security  Settings

Security  Settings

 Bypass  with  PIN

Sys. summary PIN req.

Yes

Yes

3

4

Used for 

the 

[B] key. If selected, then the keypad will skip the PIN entering procedure and will automatically enter 

the 1st user's PIN.

This settings allows to enable or disable access to 

System summary

 menu.

Service Mode 

}

System Setup 

}

Wireless Subsystem

WIRELESS SETTINGS

1

 

Wireless 

Subsystem

 

Security grade

How often the detector should send a supervision signal and what supervisory window will be in the system 
depends upon the setting 

Security grade

.

 

 Grade 1

 – supervision signal is sent every 1 hour, supervisory window is 1 hour.

 

 

 Custom

  –  supervision  signal  is  sent  every  1  hour,  supervisory  window  is  0  -  24  hour  (0  -  disables 

  

 

supervision).

 

  

 Grade 2

 – supervision signal is sent every 20 minutes, supervisory window is 20 minutes.

 

Wireless d

, starting from version 

 support

evices

2.000

 new communication mode, that can be selected in menu 

Mode

:

 

 LR

 – long range mode – distance is bigger, but due to the longer data packet the battery last shorter.

 

 

 ES

  

 

 – energy save mode – the distance is shorter, but due to the shorter data packet the battery last longer.

Grade 1

Wireless 

Subsystem

3

  Frequency

868,30 MHz

Wireless 

Subsystem

2

  Mode

LR (Long Range)

The default frequency is 868,30 MHz. 

D

epending on country of distribution the wireless devices (detectors, 

PGM outputs and remote control) can be programmed at factory to operate on different frequency. 

Receiver can 

receive a signal from transmitter when operating frequency matches.

Wireless 

Subsystem

4

  Attenuation

0 dB

Due  to  the  fact  that  there  may  be  changes  in  the  passive  environment  after  installation,  it  is  possible  to 

temporarily

 for 3dB 

attenuate

 

the radio frequency link during installation or maintenance. 

If the system will 

continue receiving signal from the detector with an attenuated radio frequency link, then it will work for sure 
under normal conditions.

 

New setting will be applied in 20 min or 1 hour time (depends on  supervisory signal 

sending frequency).

DO NOT FORGET

 to change the 

Attenuation

 setting's value to 

0dB

 when installation or maintenance works are 

finished.

Each installation typically accommodates unique user PIN codes of up to 4 digits. The 

Edit Users

 menu provides access to submenus and 

their related parameters that enable you to maintain 

u

ser PIN codes in the system. The first user

’s

 PIN code is used by the system’s owner 

or chief user. This user has access to all the menus (except 

Service mode

) and it can't be disabled.

Main menu 

}

Settings 

}

Users 

}

 Edit Users

USER PROGRAMMING

1

 

U01  User  01

 Name

User  01

It is recommended to give an appropriate name to a user. The system will use it  to send SMS or for display on 
keypad's LCD screen.

U01  User  01

 Assigned  partitions

[ENT]

3

The 

Assigned partitions

 menu enables you to assign the partition(s) in which the user (except for the 1st system 

user) will operate.

This option allows to restore current user PIN to default. Factory default user PIN depends on user's number in 
the system. System user number is shown next to letter 

U

 on top-left corner of the keypad's LCD. For example 

U01 means the 1st system user, U02 means the 2nd user, and so on. Default PIN code used by U01 (1st user ) - 
0001, U02 (2nd user) default PIN - 0002, ..., U63 (63th user) default PIN - 0063. Default PIN code is temporary 
and should be changed as soon as possible to a new one. It is recommended to change the old PIN code to one 
that will not be used as default for other users (default PIN range 0000 to 0063).

U01  User  01

 Reset  PIN  to  default

Yes

5

U01  User  01

 Timers

[ENT]

4

Used to allow users to control the system during predefined time periods. 

Note:

 if the timer is not assigned, the 

user will be able to control the system without time limitations.

U01  User  01

 Status

Enabled

2

All users that have the status mode

 

Enabled

 can control 

the 

system or its partitions.

Summary of Contents for BK4

Page 1: ... the tab Project data sending receiving 3 Once you customize the predefined template you can use it to program an individual system or thousands of systems 4 DO NOT FORGET to upload the customized template further project back to the keypad use the tab Project data sending receiving Fig 1 USB connection Upon power up of the system the keypad will display a phrase First Start Press ENT It means tha...

Page 2: ... the customized project back to the keypad use the tab Project data sending receiving MANUAL REGISTRATION OF MODULES Control panel PAS808M supports up to 7 modules and control panels PAS816 PAS832 P16 P32 P64 supports up to 15 modules If there are a few modules with incl enabled virtual modules EXT116VM on P series control panels the same default addresses in the system for example several EXM800 ...

Page 3: ...s are programmed in the system program system timers in menu Main menu Settings Timers M00 Control Panel 1 Name Control Panel It is recommended to give an appropriate name to the module The module name will appear on keypad s LCD if there will be any trouble with the module 2 M00 Control Panel Address 00 Registered module address is shown in a second row and on the upper left corner of LCD eg M00 ...

Page 4: ... MC and IR Anti Sabotage Roller Anti Sabotage No 5 6 M06 PROX8 Unknown tag No actio 13 The proximity reader has 3 options on what it must do when the unknown proximity tag is detected No action Indication module starts blinking red and starts emitting an annoying noise Indication and alarm module starts blinking red and starts emitting an annoying noise The alarm siren will be triggered after 3 at...

Page 5: ...e Roller special purpose zone loop type exluding PAS808M Wireless Z01 Door Address 00_1 A 2 Z01 Door Address 00_1 B 2 Page 5 Wireless detectors can be enrolled using serial number in a system with following firmware version or higher control panel P16 P32 P64 v 5 00 wireless zone expansion module EXT116S v 5 000 keypads KM24 KM24Aarba KM24G v 5 000 keypads KM25 v 5 000 software MASCAD v 1 9403 GSM...

Page 6: ...m is armed in Stay mode Entry Exit Forced same as Entry Exit zone but unlike a regular entry exit zone this zone can be violated before the arming Short programming manual basic information Intruder alarm system System with KM24 KM24A KM24G keypads Z01 Door Supervisory window 2h 6 Specifies how often the system checks for supervision signals identifying each of the system s wireless detectors The ...

Page 7: ...tput triggering source otherwise the PGM will not work correctly Not used unused PGM output should be programmed as Not Used FireAlarm output activates if an alarm occurs on the selected zone or module emergency keys Fire Burglary Alarm output activates if fire or burglary alarm occurs on the selected zone or module emergency keys Note output also activates when zone or module tamper conditions ar...

Page 8: ...eporting to CMS or to the user via the PSTN line PSTN Communicator Tel Number 1 8p45345464 2 Program the phone numbers as required Use the key to enter additional symbols p 3 sec pause P 10 sec pause w wait dial tone User must acknowledge the call by pressing the Ü key on the phone otherwise the control panel will call again Program the Account number This account number will be used for all repor...

Page 9: ...twork and another computer network frequently the public Internet A GSM GPRS module making a data connection must be configured with an APN to present to the network provider Contact your provider to verify the correct APN settings 4 GPRS settings Yes Send every 15 sec Periodic test The Periodic test menu enables you to set the time period that the module will automatically send a test report to t...

Page 10: ...in hours Period in hours Report time hh mm Report time hh mm x 1 1 x 01 00 xx 15 1 1 2 2 3 3 The programmed exit delay will be applied for all enabled partitions System Times Exit Delay 30 sec 1 Used for all partitions An audible Auto Arm Delay warning countdown will commence prior the automatic arming User that has right to stop auto arming can enter a valid PIN code at any time during the countd...

Page 11: ...stribution the wireless devices detectors PGM outputs and remote control can be programmed at factory to operate on different frequency Receiver can receive a signal from transmitter when operating frequency matches Wireless Subsystem 4 Attenuation 0 dB Due to the fact that there may be changes in the passive environment after installation it is possible to temporarily for 3dB attenuate the radio ...

Page 12: ... from the user U01 User 01 U01 User 01 Rights Arm Disarm Yes Clear alarm Yes Abort arming Yes All Rights Selected 7 7 All system users have all rights assigned by default However it is possible to change them The user has access to the following Arm Disarm Clear alarm Abort arming Bypass zones Edit settings View Event log Test fire zones Reporting test Run other tests Control PGM outputs Edit syst...

Page 13: ...GISTER KEYPAD KM24G PROGRAMMING WIZARD KM24G Service Mode Unregister Modules Service Mode Unregister keypad Service Mode Programming Wizard Used to unregister system modules The message First Start Press ENT will appear on keypad s LCD screen when this procedure will end Used to unregister the keypad from the system Step by step programming wizzard with explanations and wiring schemes 5 7 6 Servic...

Page 14: ...Use SERIALaccount Account number Protocol Transport Receiver No 2 Use as backup for Rec 1 Address Port Use SERIALaccount Account number Protocol Transport Periodic test Send every Obtain IPautomatic IPaddress Subnet mask Gateway Obtain DNS automatic DNS server 1 DNS server 2 Periodic Test Settings Period in hours Period in days Period time hh mm Name In Use Exit Delay No Entry Delay Arming timer P...

Reviews: