hort programming manual is recommended for professional installers who are experienced in 

the 

installation

 of 

 intruder alarm 

systems  and have already read the S

ECOLINK

 wiring manual. 

The wiring manual must be read b

efore the installation to avoid 

accidents

 with high voltage and temperatur

e.

SAFETY WARNINGS

The device must be connected to AC power supply with Protective Earthing. Cable color and purpose

:

 Phase or Live line (L) -   black or 

brown cable, Neutral line (N)  - blue cable, Protective Earth line (PE) - green cable with a vertical yellow stripe. Only double isolated cables 

2

with cross-sectional area of no less than 0,75 mm  shall be used for 230V power supply.

Additional automatic two-pole circuit breaker should be installed in AC electric power circuit in order to prevent over-current and short 
circuits. The circuit breaker should be placed close to the system's housing and should be easily reached. Full shutdown could be done by 
turning off the 230V AC main power supply with automatic two-pole circuit breaker and by disconnecting  the battery. Before performing 
any installation work or maintenance ALWAYS disconnect the device from the power supply.

DEFAULT TEMPLATE

STARTING THE SYSTEM WITH A SINGLE KEYPAD

The system is shipped from the factory with specific default values (further default template) suitable for a typical installation. If the default 
template is suitable for your installation, then programming can be simplified. If template is not suitable for your 

installation

, then you can 

easily customize th

is

 default template with the software MASCAD. Download MASCAD at www.secolink.eu prior to installation:

On keypad's LCD screen:

Short  programming manual - basic information 

Intruder alarm system

System with  

KM24, KM24A

, KM24G keypads

Entering

Service

USB cable

KM24x

MASC

USB

Computer

Page 

1

Registering

From 

 

KM24

  to

CP

Leaving

Service

Note:

 the default template can be

 different

 

for different countries. Check 

sticker

 on the 

keypad  for 

a country prefix or pre-installed template code.  Example: KM

24G_EN.

  1.Connect the keypad to your computer using a USB cable (keypad should not be connected to 
system data bus).
  2. Download default template from the keypad to software MASCAD (use the tab 

Project data 

sending/receiving

).

  3.Once you customize the predefined template, you can use it to program an individual system or 
thousands of systems.
  4. DO NOT FORGET to upload the customized template (further project) back to the keypad (use 
the tab 

Project data sending/receiving

).

Fig. 1 USB connection

Upon power-up of the system, the keypad will display a phrase 

First Start Press [ENT].

 It mean

s

 that the 

keypad

 is ready to 

run an 

automati

c

 

module  registration  procedure  and  later  send  the  default  template  (or  customized  project)  to  the  control  panel  and  all 

successfully registered system modules.

Processing..

Press

 the

 [ENT] key.

Template is being sent 

to the system.

Registration of modules is 

in progress.

Entering Service.

Leaving Service.

STARTING THE SYSTEM WITH 

MULTIPLE

 KEYPADS

No Control Address 00

 phrase will display upon power-up of the system with multiple keypads.

 

It means that the keypad ha

s

 the same 

address in the system as the other keypads or modules.

 Press

 the

 [

Ü

]

 

key 

on a keypad which will become 

the

 primary keypad. 

The p

rimary 

keypad should b

ecome the

 one which has a customized project

 OR it could be any keypad if the

 default template is not customized

.

 

When 

the 

[

Ü

]

 

key 

is pressed the keypad will emit a short audible signal 

and

 a

 phrase

 

First Start Press [ENT]

 will appear on 

the 

screen

Simply press 

[ENT]

 i

f the 

primary

 keypad contains a 

customized project

 with precise 

module addressing

. If the 

primary

 keypad  contains 

just a 

default 

template

, then

 

use

 

keys 

[1], [2], [3], [4], [5] to manually 

assign

 the address 

to

 each keypad. 

When all addresses of 

the 

keypads 

are 

assigned

, return to the primary keypad and press the 

[ENT]

 key.

 All keypads will be registered according to their addresses, which were 

First Start

Press [ENT]

Press

 the

 [

Ü

] key.

Enter the address

Primary keypad

Used. Choose another.

Processing ...

Assigned address 02.

No Control

Address 00

No Control

Address 00

No Control

Address 0

2

Processing ...

  Selecting the primary keypad :

  Manually assigning addresses to other keypads:

First Start

Press [ENT]

No Control

Address 0

3

Used

For  a  small  system  with  a  few  keypads,  it  is 
recommended   to choose 

addresses of keypads

 in 

0

1 - 

0

4 range, and for 

a

 

large

 system in 

0

1 - 

0

4 and 10 

- 15 range

s

This is done in order to not disturb

 the 

default  addresses  of  other  modules  with  the 
addresses of  the keypads.

given  manually. 

Note:

  the  keypad  will  remain 

unregistered if you 

will forget

 to assign the address. 

Page 1

Summary of Contents for BK4

Page 1: ... the tab Project data sending receiving 3 Once you customize the predefined template you can use it to program an individual system or thousands of systems 4 DO NOT FORGET to upload the customized template further project back to the keypad use the tab Project data sending receiving Fig 1 USB connection Upon power up of the system the keypad will display a phrase First Start Press ENT It means tha...

Page 2: ... the customized project back to the keypad use the tab Project data sending receiving MANUAL REGISTRATION OF MODULES Control panel PAS808M supports up to 7 modules and control panels PAS816 PAS832 P16 P32 P64 supports up to 15 modules If there are a few modules with incl enabled virtual modules EXT116VM on P series control panels the same default addresses in the system for example several EXM800 ...

Page 3: ...s are programmed in the system program system timers in menu Main menu Settings Timers M00 Control Panel 1 Name Control Panel It is recommended to give an appropriate name to the module The module name will appear on keypad s LCD if there will be any trouble with the module 2 M00 Control Panel Address 00 Registered module address is shown in a second row and on the upper left corner of LCD eg M00 ...

Page 4: ... MC and IR Anti Sabotage Roller Anti Sabotage No 5 6 M06 PROX8 Unknown tag No actio 13 The proximity reader has 3 options on what it must do when the unknown proximity tag is detected No action Indication module starts blinking red and starts emitting an annoying noise Indication and alarm module starts blinking red and starts emitting an annoying noise The alarm siren will be triggered after 3 at...

Page 5: ...e Roller special purpose zone loop type exluding PAS808M Wireless Z01 Door Address 00_1 A 2 Z01 Door Address 00_1 B 2 Page 5 Wireless detectors can be enrolled using serial number in a system with following firmware version or higher control panel P16 P32 P64 v 5 00 wireless zone expansion module EXT116S v 5 000 keypads KM24 KM24Aarba KM24G v 5 000 keypads KM25 v 5 000 software MASCAD v 1 9403 GSM...

Page 6: ...m is armed in Stay mode Entry Exit Forced same as Entry Exit zone but unlike a regular entry exit zone this zone can be violated before the arming Short programming manual basic information Intruder alarm system System with KM24 KM24A KM24G keypads Z01 Door Supervisory window 2h 6 Specifies how often the system checks for supervision signals identifying each of the system s wireless detectors The ...

Page 7: ...tput triggering source otherwise the PGM will not work correctly Not used unused PGM output should be programmed as Not Used FireAlarm output activates if an alarm occurs on the selected zone or module emergency keys Fire Burglary Alarm output activates if fire or burglary alarm occurs on the selected zone or module emergency keys Note output also activates when zone or module tamper conditions ar...

Page 8: ...eporting to CMS or to the user via the PSTN line PSTN Communicator Tel Number 1 8p45345464 2 Program the phone numbers as required Use the key to enter additional symbols p 3 sec pause P 10 sec pause w wait dial tone User must acknowledge the call by pressing the Ü key on the phone otherwise the control panel will call again Program the Account number This account number will be used for all repor...

Page 9: ...twork and another computer network frequently the public Internet A GSM GPRS module making a data connection must be configured with an APN to present to the network provider Contact your provider to verify the correct APN settings 4 GPRS settings Yes Send every 15 sec Periodic test The Periodic test menu enables you to set the time period that the module will automatically send a test report to t...

Page 10: ...in hours Period in hours Report time hh mm Report time hh mm x 1 1 x 01 00 xx 15 1 1 2 2 3 3 The programmed exit delay will be applied for all enabled partitions System Times Exit Delay 30 sec 1 Used for all partitions An audible Auto Arm Delay warning countdown will commence prior the automatic arming User that has right to stop auto arming can enter a valid PIN code at any time during the countd...

Page 11: ...stribution the wireless devices detectors PGM outputs and remote control can be programmed at factory to operate on different frequency Receiver can receive a signal from transmitter when operating frequency matches Wireless Subsystem 4 Attenuation 0 dB Due to the fact that there may be changes in the passive environment after installation it is possible to temporarily for 3dB attenuate the radio ...

Page 12: ... from the user U01 User 01 U01 User 01 Rights Arm Disarm Yes Clear alarm Yes Abort arming Yes All Rights Selected 7 7 All system users have all rights assigned by default However it is possible to change them The user has access to the following Arm Disarm Clear alarm Abort arming Bypass zones Edit settings View Event log Test fire zones Reporting test Run other tests Control PGM outputs Edit syst...

Page 13: ...GISTER KEYPAD KM24G PROGRAMMING WIZARD KM24G Service Mode Unregister Modules Service Mode Unregister keypad Service Mode Programming Wizard Used to unregister system modules The message First Start Press ENT will appear on keypad s LCD screen when this procedure will end Used to unregister the keypad from the system Step by step programming wizzard with explanations and wiring schemes 5 7 6 Servic...

Page 14: ...Use SERIALaccount Account number Protocol Transport Receiver No 2 Use as backup for Rec 1 Address Port Use SERIALaccount Account number Protocol Transport Periodic test Send every Obtain IPautomatic IPaddress Subnet mask Gateway Obtain DNS automatic DNS server 1 DNS server 2 Periodic Test Settings Period in hours Period in days Period time hh mm Name In Use Exit Delay No Entry Delay Arming timer P...

Reviews: