Short programming manual - basic information
Intruder alarm system
System with
KM24, KM24A
, KM24G keypads
5
M01 Keypad
Assigned partitions
[ENT]
All partitions are usually assigned to the keypad by default. All events related to all partitions are shown on
keypad's LCD. If there is a need to monitor only one of all enabled partitions, then assign this particular partition
to the keypad. Use [ENT] to enter the menu, then press [#] to assign partition to the keypad. Save changes by
pressing the [ENT] key.
7
8
9
M01 Keypad
Fire Alarm
Medical Alarm
Panic Alarm
Panic silent
Yes
No
No
No
The keypads have additional keys dedicated for emergency conditions. These can be activated by pressing
both keys at the same time. However, in some places like
a
corridor it is recommended to disable emergency
keys to prevent false alarms.
Extended settings for
PROX8 module
:
Extended settings for EXT116S or EXT116VM
module
s:
M06 PROX8
Assigned partitions
[ENT]
5
All partitions by default are usually assigned to the proximity reader PROX8. All events related to all partitions
are shown on proximity reader's LED. If there is a need to monitor only one of all enabled partitions, then assign
this particular partition to the proximity reader. Use [ENT] to enter the menu, then press
the
[#] key to assign
a
partition to the
proximity reader
. Save changes by pressing the [ENT] key.
This setting is related to entry/exit counting when the module is installed indoors and outdoors. If proximity
reader is installed outdoors, then the Entry/Exit delay is excluded.
M06 PROX8
Installation
Outdoor
6
The p
referred arming mode will appear as a first option. With preferred arming mode selected correctly the
user will spend less time on arming. Arming mode is indicated by a color of PROX8 LED:
Away
- red color;
Night
- blue color;
Stay
- green color;
Max Away
- white color.
Note:
if there is a need for only 1 arming mode, program all options with the same arming mode.
M06 PROX8
Preferred mode
Second mode
Third mode
Fourth mode
Away
7
8
9
10
M06 PROX8
Sound
Yes
11
The p
roximity reader has a buzzer for audible notifications which can be enabled or disabled.
M06 PROX8
Hide LED indication
Yes
12
M06
EXT116S
MC and IR Anti-Sabotage
Roller Anti-Sabotage
No
5
6
M06 PROX8
Unknown tag
No actio
13
The p
roximity reader has 3 options on what it must do when the unknown proximity tag is detected:
No action
Indication
- module starts blinking red and starts emitting an annoying noise.
Indication and alarm
-module starts blinking red and starts emitting an annoying noise. The alarm siren will
be triggered after 3 attempts to control the system with an unknown tag.
The proximity reader can be programmed to indicate present status of the system on LED for a short period of
time when
the
tag is near
a sensitive area of the module or it can indicate the status continuously.
M06 PROX8
Operation mode
Small syst
14
The meaning of LED indication depends on module operation mode:
Small System
(up to 3 partitions)
-
this operation mode is useful when the system has 1 or 2 partitions
enabled.
1st and 2nd module LED indicates the arming mode in 1st and 2nd partitions respectively;
3rd LED indicates system troubles;
4th LED indicates an alarm, an alarm memory
, n
ot ready status
(open zones)
, and zone bypass.
If the system has 3 partitions enabled, then the 3rd LED will indicate the arming mode of the 3rd partition.
Troubles will be indicated on the 4th LED. Color meaning:
Red color - Alarm;
Red slow blinking - Alarm memory;
Green color - Not Ready;
Yellow color - Trouble;
Blue color - Bypassed Zone.
Large System
(4 partitions)
-
each partition is assigned to different module’s LED. Module LED indicates all
information (arming mode, alarm, alarm memory, troubles, and zone bypass).
ZONE PROGRAMMING
Zones, in the context of an alarm system, are individual
detectors
. If the alarm gets triggered, the system records the zones that were
tripped, allowing
the
user to know the exact point of action. Zones also help the monitoring station to know whether they should call the
police or fire department upon an alarm. Each zone must be assigned to a partition.
Service Mode
}
System Setup
}
Zones
1
Z01 Door
Name
Door
It is recommended to give an appropriate name to the zone. This name will be used by the system for SMS
sending or for display on keypad's LCD screen and etc.
Page 4
Max Away
Stay
Night
Used to secure communication between the detector and a receiver. When this feature is turned on
,
the detector
will consume more battery power and battery life will decrease.
No
Extended settings for
keypads
: