Short  programming manual - basic information 

Intruder alarm system

System with  

KM24, KM24A

, KM24G keypads

5

 

M01   Keypad

 Assigned  partitions

[ENT]

All partitions are usually assigned to the keypad by default. All events related to all partitions are shown on 
keypad's LCD. If there is a need to monitor only one of all enabled partitions, then assign this particular partition 
to the keypad. Use [ENT] to enter the menu, then press [#] to assign partition to the keypad. Save changes by 
pressing the [ENT] key.

7

 

8

9

 

M01   Keypad

 Fire  Alarm
 Medical  Alarm
 Panic  Alarm
 Panic  silent

Yes

No
No
No

The keypads have additional keys dedicated for emergency conditions. These can be activated by pressing 
both keys at the same time. However, in some places like 

corridor it is recommended to disable emergency 

keys to prevent false alarms.

Extended settings for 

PROX8 module

:

Extended settings for EXT116S or EXT116VM

 module

s:

M06   PROX8

 Assigned  partitions

[ENT]

5

All partitions by default are usually assigned to the proximity reader PROX8. All events related to all partitions 
are shown on proximity reader's LED. If there is a need to monitor only one of all enabled partitions, then assign 
this particular partition to the proximity reader. Use [ENT] to enter the menu, then press 

the 

[#] key to assign

 a 

partition to the 

proximity reader

. Save changes by pressing the [ENT] key.

This setting is related to entry/exit counting when the module is installed indoors and outdoors. If proximity 
reader is installed outdoors, then the Entry/Exit delay is excluded.

M06   PROX8

Installation

Outdoor

6

The p

referred arming mode will appear as a first option. With preferred   arming   mode selected correctly the 

user will spend less time on arming. Arming  mode is indicated by a color of PROX8 LED:
     

Away

 - red color;

     

Night

 - blue color;

     

Stay

 - green color;

     

Max Away

 - white color.

Note:

 if there is a need for only 1 arming mode, program all options with the same arming mode.

M06   PROX8

 Preferred  mode
 Second  mode
 Third  mode
 Fourth  mode

Away

7

8

9

10

M06   PROX8

 Sound

Yes

11

The p

roximity reader has a buzzer for audible notifications which can be enabled or disabled.

M06   PROX8

 Hide  LED  indication

Yes

12

M06  

EXT116S

 MC and IR Anti-Sabotage
 Roller Anti-Sabotage

No

5

6

M06   PROX8

 Unknown tag

No actio

13

The p

roximity reader has 3 options on what it must do when the unknown proximity tag is detected:

     

No action

     

Indication

 - module starts blinking red and starts emitting an annoying noise.

     

Indication and alarm

 -module starts blinking red and starts emitting an annoying noise. The alarm siren will 

be triggered after 3 attempts to control the system with an unknown tag.

The proximity reader can be programmed to indicate present status of the system on LED for a short period of 
time when 

the 

tag is near

 

a sensitive area of the module or it can indicate the status continuously.

M06   PROX8

 Operation  mode

Small  syst

14

The meaning of LED indication depends on module operation mode:
     

Small System 

(up to 3 partitions)

 - 

this operation mode is useful when the system has 1 or 2 partitions 

enabled.

       

1st and 2nd module LED indicates the arming mode in 1st and 2nd partitions respectively;

       

3rd LED indicates system troubles;

       

4th LED indicates an alarm, an alarm memory

, n

ot ready status

 (open zones)

, and zone bypass.

If the system has 3 partitions enabled, then the 3rd LED will indicate the arming mode of the 3rd partition. 
Troubles will be indicated on the 4th LED. Color meaning:

       

Red color - Alarm;

       

Red slow blinking - Alarm memory;

       

Green color - Not Ready;

       

Yellow color - Trouble;

       

Blue color - Bypassed Zone.

     

Large System

 (4 partitions)

 - 

each partition is assigned to different module’s LED. Module LED indicates all 

information (arming mode, alarm, alarm memory, troubles, and zone bypass).

ZONE PROGRAMMING

Zones, in the context of an alarm system, are individual 

detectors

. If the alarm gets triggered, the system records the zones that were 

tripped, allowing

 the

 user to know the exact point of action. Zones also help the monitoring station to know whether they should call the 

police or fire department upon an alarm. Each zone must be assigned to a partition.

Service Mode 

}

System Setup 

}

Zones

1

 

Z01   Door

 Name

Door

It is recommended to give an appropriate name to the zone. This name will be used by the system for SMS  
sending or for display on keypad's LCD screen and etc.

Page 4

Max Away

Stay

Night

Used to secure communication between the detector and a receiver. When this feature is turned on

,

 the detector 

will consume more battery power and battery life will decrease.

No

Extended settings for 

keypads

:

Summary of Contents for BK4

Page 1: ... the tab Project data sending receiving 3 Once you customize the predefined template you can use it to program an individual system or thousands of systems 4 DO NOT FORGET to upload the customized template further project back to the keypad use the tab Project data sending receiving Fig 1 USB connection Upon power up of the system the keypad will display a phrase First Start Press ENT It means tha...

Page 2: ... the customized project back to the keypad use the tab Project data sending receiving MANUAL REGISTRATION OF MODULES Control panel PAS808M supports up to 7 modules and control panels PAS816 PAS832 P16 P32 P64 supports up to 15 modules If there are a few modules with incl enabled virtual modules EXT116VM on P series control panels the same default addresses in the system for example several EXM800 ...

Page 3: ...s are programmed in the system program system timers in menu Main menu Settings Timers M00 Control Panel 1 Name Control Panel It is recommended to give an appropriate name to the module The module name will appear on keypad s LCD if there will be any trouble with the module 2 M00 Control Panel Address 00 Registered module address is shown in a second row and on the upper left corner of LCD eg M00 ...

Page 4: ... MC and IR Anti Sabotage Roller Anti Sabotage No 5 6 M06 PROX8 Unknown tag No actio 13 The proximity reader has 3 options on what it must do when the unknown proximity tag is detected No action Indication module starts blinking red and starts emitting an annoying noise Indication and alarm module starts blinking red and starts emitting an annoying noise The alarm siren will be triggered after 3 at...

Page 5: ...e Roller special purpose zone loop type exluding PAS808M Wireless Z01 Door Address 00_1 A 2 Z01 Door Address 00_1 B 2 Page 5 Wireless detectors can be enrolled using serial number in a system with following firmware version or higher control panel P16 P32 P64 v 5 00 wireless zone expansion module EXT116S v 5 000 keypads KM24 KM24Aarba KM24G v 5 000 keypads KM25 v 5 000 software MASCAD v 1 9403 GSM...

Page 6: ...m is armed in Stay mode Entry Exit Forced same as Entry Exit zone but unlike a regular entry exit zone this zone can be violated before the arming Short programming manual basic information Intruder alarm system System with KM24 KM24A KM24G keypads Z01 Door Supervisory window 2h 6 Specifies how often the system checks for supervision signals identifying each of the system s wireless detectors The ...

Page 7: ...tput triggering source otherwise the PGM will not work correctly Not used unused PGM output should be programmed as Not Used FireAlarm output activates if an alarm occurs on the selected zone or module emergency keys Fire Burglary Alarm output activates if fire or burglary alarm occurs on the selected zone or module emergency keys Note output also activates when zone or module tamper conditions ar...

Page 8: ...eporting to CMS or to the user via the PSTN line PSTN Communicator Tel Number 1 8p45345464 2 Program the phone numbers as required Use the key to enter additional symbols p 3 sec pause P 10 sec pause w wait dial tone User must acknowledge the call by pressing the Ü key on the phone otherwise the control panel will call again Program the Account number This account number will be used for all repor...

Page 9: ...twork and another computer network frequently the public Internet A GSM GPRS module making a data connection must be configured with an APN to present to the network provider Contact your provider to verify the correct APN settings 4 GPRS settings Yes Send every 15 sec Periodic test The Periodic test menu enables you to set the time period that the module will automatically send a test report to t...

Page 10: ...in hours Period in hours Report time hh mm Report time hh mm x 1 1 x 01 00 xx 15 1 1 2 2 3 3 The programmed exit delay will be applied for all enabled partitions System Times Exit Delay 30 sec 1 Used for all partitions An audible Auto Arm Delay warning countdown will commence prior the automatic arming User that has right to stop auto arming can enter a valid PIN code at any time during the countd...

Page 11: ...stribution the wireless devices detectors PGM outputs and remote control can be programmed at factory to operate on different frequency Receiver can receive a signal from transmitter when operating frequency matches Wireless Subsystem 4 Attenuation 0 dB Due to the fact that there may be changes in the passive environment after installation it is possible to temporarily for 3dB attenuate the radio ...

Page 12: ... from the user U01 User 01 U01 User 01 Rights Arm Disarm Yes Clear alarm Yes Abort arming Yes All Rights Selected 7 7 All system users have all rights assigned by default However it is possible to change them The user has access to the following Arm Disarm Clear alarm Abort arming Bypass zones Edit settings View Event log Test fire zones Reporting test Run other tests Control PGM outputs Edit syst...

Page 13: ...GISTER KEYPAD KM24G PROGRAMMING WIZARD KM24G Service Mode Unregister Modules Service Mode Unregister keypad Service Mode Programming Wizard Used to unregister system modules The message First Start Press ENT will appear on keypad s LCD screen when this procedure will end Used to unregister the keypad from the system Step by step programming wizzard with explanations and wiring schemes 5 7 6 Servic...

Page 14: ...Use SERIALaccount Account number Protocol Transport Receiver No 2 Use as backup for Rec 1 Address Port Use SERIALaccount Account number Protocol Transport Periodic test Send every Obtain IPautomatic IPaddress Subnet mask Gateway Obtain DNS automatic DNS server 1 DNS server 2 Periodic Test Settings Period in hours Period in days Period time hh mm Name In Use Exit Delay No Entry Delay Arming timer P...

Reviews: