By default, the LAN module is set to obtain IP automatically, which should be kept only if your ISP supports
DHCP or you are connecting through a dynamic IP address. If you are required to use a permanent IP address to
connect to the Internet, select
No
. In this case all IP settings must be manually entered.
IP address
- enter IP address of the module in the network.
Subnet mask
- enter a mask of the subnet in which the module works.
Gateway
- the default gateway provides a default route for TCP/IP hosts to use when communicating with
other hosts on remote networks.
DNS server 1 & 2
- DNS technology allows you to type names into receivers No.1 or No.2 address fields
(www.alarmserver.net) and the LAN module will automatically find that IP address on the internet.
4
LAN settings
Yes
Obtain DNS automatic.
Yes
Obtain IP automatic.
5
DNS server 2
4.4.4.4
4
LAN settings
No
IP address
Subnet mask
Gateway
DNS server 1
192.168.0.248
255.255.255.0
192.168.0.254
8.8.8.8
Obtain IP automatic.
Short programming manual - basic information
Intruder alarm system
System with
KM24, KM24A
, KM24G keypads
The
Periodic Test Settings
menu contains parameters that enable the routing of a periodic test event to CMS receivers.
The
System times
settings
menu contains parameters that specify the duration of an action
.
Service Mode
}
Report settings
}
Periodic test settings
Service Mode
}
System Setup
}
System times
PERIODIC TEST SETTINGS
SYSTEM TIMES SETTINGS
Set the test time and hourly/daily interval for periodic test reporting.
Daily reporting - use the keypad’s numeric keys [0] to [9] to type in the time of the
day (in 24-hour format) for
periodic test reports to be sent. Use the list below to specify the daily testing intervals:
0 -
daily reporting is disabled
1
- Every day;
2
- Every other day;
...
30 Every 30th day;
31 Every 31th day.
Hourly reporting (except systems with PAS808M) - use the keypad’s numeric keys [0] to [9] to type in the hour
interval and the minute at the hour for periodic test reports to be sent. Disable the periodic reporting by setting
the
Period in hours
to 0.
Periodic Test Settings
Periodic Test Settings
Period in days
Period in days
Period in hours
Period in hours
Report time (hh:mm)
Report time (hh:mm)
x
1
1
x
01:00
xx:15
1
1
2
2
3
3
The programmed exit delay will be applied for all enabled partitions.
System Times
Exit Delay
30 sec
1
Used for all partitions. An audible
Auto Arm Delay
(warning) countdown will commence prior the automatic
arming. User, that has right to stop auto arming, can enter a valid PIN code at any time during the countdown to
stop auto arming.
The buzzer (or loudspeaker) housed inside the keypad emits (annunciates) sounds in case of alarm. The
duration of alarm sound is programmable within a 1 - 255 seconds range.
System Times
KM24 Alarm Time
180 sec
2
System Times
Auto Arm Delay
30 sec
3
Event reports from entry zones to the CMS are delayed for 30 seconds after they are detected. Select
Yes
if the
event report should be sent immediately.
System Times
Immediate entry alrm
Yes
8
In case of AC power loss, this parameter specifies the delay period before reporting the event.
System Times
AC Loss Rep. Delay
10 min
5
This time is related to special arming mode
Pre-alarm
. When a pre-alarm zone is violated, the system will trigger
the siren and a keypad buzzer (loudspeaker). The duration of pre-alarm is programmable within a 1 - 255
seconds range.
System Times
Pre-Alarm Time
10 sec
4
Implemented on detection of smoke or fire for verification. When smoke of fire zone is violated, the system will
reset all smoke or fire detectors, then wait for detectors to settle. Detector's settling time is programmable within
a 1 - 255 seconds range.
System Times
Detector Settle Time
5 sec
6
Implemented on detection of smoke or fire for verification. When smoke or fire zone is violated, the system will
reset these detectors, then wait for detectors to settle. If a subsequent detection occurs in the same zone within
the time that is programmed in
Fire Verification Time
, the system will emit a fire alarm.
System Times
Fire Verific. Time
15 sec
7
SECURITY SETTINGS
Service Mode
}
System Setup
}
Security Settings
Arm with PIN
Yes
Security Settings
1
Used for
the
[ ] key. If selected, then the keypad will skip the PIN entering procedure and will automatically enter
the 1st user's PIN.
Pre-Alarm with PIN
Yes
Security Settings
2
Used for
the
[ ] key. If selected, then the keypad will skip the PIN entering procedure and will automatically enter
the 1st user's PIN.
Page 10