Configuring an Ethernet (E-Series) Module
This section applies only to Ethernet (E-series) SeaI/O modules. For all other SeaI/O modules, refer to
the Configuring a “Base” SeaI/O Module and Configuring Expansion Modules sections on the previous
pages.
Verify that SeaMAX software has been installed successfully and that an Ethernet SeaI/O module is connected
directly to your computer using the yellow crossover cable supplied with your module. This module will become
the “base” module.
All Ethernet SeaI/O modules are shipped with DHCP enabled. When you first connect an Ethernet SeaI/O module
to the network, the status LEDs on the front of the module will blink while it searches for a DHCP server. Once
it receives an IP address, the status LEDs will remain on.
If no DHCP server is available, the Ethernet SeaI/O module will default to a random IP address in the range
169.254.x.x. To discover the SeaI/O module’s IP address, start the Ethernet Config utility (Start
→
All Programs
→
Sealevel SeaMAX
→
Ethernet Config) installed with SeaMAX.
Click on
the “Search for SeaI/O Devices” button and the ‘Available SeaI/O Devices’ pane should refresh with any
Ethernet or Wireless SeaI/O modules that are found on the network. Select one of the modules in the list by
clicking on it. You can update the settings in the Device Network Settings pane and then confirm these changes
by clicking the “Apply Changes” button. The module list should refresh, indicating that your changes were
successful.